Amprobe ROBIN KMP7010 Manual del usuario - Página 14

Navegue en línea o descargue pdf Manual del usuario para Equipos de prueba Amprobe ROBIN KMP7010. Amprobe ROBIN KMP7010 16 páginas. Ground resistance tester

Amprobe ROBIN KMP7010 Manual del usuario
Simple measurement(use simple 2-Wires test leads for measurement): This
method will be used when the auxiliary earth stakes cannot be used. Use the
exposed earth resistance object from the ground as earth, like metal water
bath, water pipe, ground wire, building earth, also can use 2-wires test leads
method (E and S&H terminals).Connection diagram is as below:
Supply Transformer
Primary
Side
Reference Earthed
Electrode

SPECIFICATION

At Temperature: 20±5°C; Humidity: 45%~75% RH; Altitude ≤2000 meter)
Operating temperature: 5°C~40°C (32°F to 104°F)
Relative Humidity: ≤80%RH
Altitude: ≤2000 meter
Storage Condition:
A) Temperature: -20°C~60°C(-4°F to 152°F)
B) Relative Humidity: ≤90%
Product Size: 160mm x 101mm x 71mm (6.3 x 3.98 x 2.79in)
Product Net Weight: About 500g (1.1 lb)
CE Regulation Compliance:
EN 61010-1 CAT III 400V, EN 61010-2-31 for test leads
EN 61557-1, EN 61557-5
EN 61326-1 (EMC)
Pollution degree II, Class II equipment (double insulation)
IP40 as per EN 60529
Secondary
Side
Earthed Electrode
Under Test
Red
Green
9