AMSEC ESL15 Manual de instrucciones - Página 4

Navegue en línea o descargue pdf Manual de instrucciones para Cerraduras AMSEC ESL15. AMSEC ESL15 10 páginas. Electronic lock
También para AMSEC ESL15: Instrucciones de uso (4 páginas)

AMSEC ESL15 Manual de instrucciones
American Security Products Co.
Subordinate User Control - The Master User has the option of allowing, or not allowing, certain capabilities of the
Subordinate Users as follows.
The Subordinate User changing their own combination. (F60)
o
Two Subordinate Users opening the safe in Dual Combo Mode. (F31)
o
The Subordinate User authorizing Armored Car Time Delay Bypass. (F41)
o
Dual Control - This feature provides a higher level of security, where two different combinations are required to open
the safe.
This feature must be Enabled (F30).
o
When Dual Control is Enabled, the lock requires two Users key their individual combinations, one after the
o
other, before the lock will open.
The second User has 10 seconds to start code entry before the system discards the login and goes to sleep.
o
After the first User keys a valid combination, a short warbling tone is sounded, and the second User is then
o
required to key a valid code.
If no second code is keyed within 10 seconds, the lock goes to the resting condition and the process must be
o
started again.
The two User Codes must be different Users.
o
A complementing feature can be enabled (F31) that prevents two subordinate Users from opening the safe. If
o
this mode is Enabled, the Manager must be one of the two Users entering valid combinations.
Duress Alarm - This feature allows a User to secretly signal that they are under Duress, typically in the act of being
forced to open the safe in a robbery situation.
This feature must be Enabled (F20).
o
This feature requires that one of the optional Expansion Modules (ESL20EXP1, ESL20EXP2 or ESL20EXP3) is
o
attached to provide electrical connection to external systems like alarms and monitoring services.
When a User keys a combination, finishing the code entry with the last number of the combination either 1
o
digit high, or 1 digit low, Duress output relay in the Expansion Module responds with a contact closure of for
one (1) second.
The Lock opens normally, allowing the User to open the safe, without revealing they have sent a silent alert.
o
This Duress output contact closure is the same as if someone had pushed a "panic" button to summon help.
o
By signaling secretly at the safe, the User doesn't risk angering the robber and risking possible personal injury.
Reset All Functions - A function has been provided to reset all the functions to what is considered "default" settings.
It disables all of the various modes, deletes all the Users and their codes, and cleans up any unknown settings.
This feature is executed by F99, and a confirming acknowledgement.
o
This is useful tool to get a fresh start after programming has been lost track of or for personnel changes at the
o
Master User level.
Revision A
ESL15 Operating Instructions
Page 4 of 10
Released Aug. 9, 2018