Electrolux Air-O-Chill 726782 Especificación

Navegue en línea o descargue pdf Especificación para Congelador Electrolux Air-O-Chill 726782. Electrolux Air-O-Chill 726782 4 páginas. Blast chiller/freezers 70-70kg

Electrolux Air-O-Chill 726782 Especificación
Electrolux air-o-chill
Blast Chiller/Freezers 70-70kg
Chilling means bringing the temperature of cooked food from +90ºC to +3°C in a short time lap which does not allow
bacterial growth .Electrolux Blast Chillers reduce temperature from +90ºC to +3°C at food core in less than 90 minutes:
the model detailed on this sheet performs this cycle up to a 70 kg full load. After the Blast Chilling a holding cycle starts
automatically to respectively maintain food at +3 and -18°C. Blast chilled food has a solid 5 days shelf life without loss of
flavour, nutritional values and weight. The opportunity to prepare in a single shot the food to be used in different times
during the week enables a better work scheduling and therefore a sensible reduction in labour costs.
OPERATING MODES
Cruise: the chiller automatically sets
the parameters for the quickes and
best chilling (it works by probe).
Soft Chilling (Air temperature –2°C).
Hard Chilling (Air temperature
–20°C).
Shock freezing (Low air temperature
adjustable up to -41 ºC.)
Holding at +3°C or -18ºC
(automatically activited at the end of
each probe driven cycle).
All the probe-driven cycles feature
ARTE (Algorithm for Remaining Time
Estimation) to make planning the
activities easier.
Turbo cooling: the chiller works
continuously at the desired
temperature. Ideal for continuous
production.
It is possible to operate by time or
by probe.
The control unit provides several
operating settings: time/core
temperature according to NF and UK
regulations, time/air
temperature/probe personalised
according to national regulations,
sterilizing cycle: UV lamps built-in (on
request), 3 single sensor core
temperature probes (as accessory),
ideal for meats, automatic defrosting
and manual defrosting. All parameters
are programmable.
3-sensor core probe as standard.
The control unit provides two large
displays to read out: time, core
temperature, cycle countdown,
alarms, service information.
Two specialized cycles, P1 brings
down the ice-cream temperature to
-14°C (measured at the core when
probe is inserted). Once set
temperature is reacheed, the
temporary maintenance phase
automatically begins, holding the
-14°C temperature. P2 sets
temperature to -36°C / -40°C for an
indefinite amount of time, maintaining
the ventilation active. Temperature is
adjustable up to -40°C without
interrupting the cycle, allowing
ice-cream to be kept longer in the
freezer.
All information related to the
different operating models are
recorded: date, time, cycle, core
temperature, holding temperature,
HACCP accordance.
An audible alarm starts when the
cycle ends or terminates abnormally.
726105