ANDI MPK1-09CR-QB8 Manual de servicio - Página 16

Navegue en línea o descargue pdf Manual de servicio para Aire acondicionado ANDI MPK1-09CR-QB8. ANDI MPK1-09CR-QB8 20 páginas. Room air conditioner

Andi-Co Australia Pty Ltd
the display board.
4.5 To replace the Main Control board.
Remove the screws fixing the enclosure cover.
Take care of the wiring diagram on the cover. The
wiring diagram is important for reference when
wiring.
Pay attention to the wires in the enclosure.
Service manual for K1 portable Series
1
2
3
4
1: Terminate to display board
2: Terminate to condenser fan motor
3: Out-put of transformer
4: Terminate to evaporator fan motor
5: Terminate to compressor
6: Terminates (N) to condenser fan motor, electric
heater, pump, power cord, compressor
capacitor
7: Terminate to electric heater
8: Terminate (L) to power cord
9: Terminate (L) to pump
10: Terminate to input of transformer
Take care to the grounding wires if need to
disconnect.
15
5
6
7
8
9
10