Atlas Copco PHE 6 S Instrucciones de reparación - Página 16

Navegue en línea o descargue pdf Instrucciones de reparación para Taladro Atlas Copco PHE 6 S. Atlas Copco PHE 6 S 18 páginas.

1
PHE 6 H:
Press the rotary shaft seal (6) into the
Mounting the
bearing housing (8).
bearing housing
2
Fit the bearing housing (8) with the
O-ring (7) to the gear housing and
fasten it with secured screws (9).
3
Fit the nosepiece (2) to the bearing
housing (8) and fasten it with secured
screws (3).
4
Push the plastic housing (1) over the gear
housing from the front and secure it with
the connecting ring.
5
Push the back part of the housing (5) over
the gear housing from behind and fasten it
with the screws (4).
1
Mounting the
Push the insulating disk (5) and the
armature
ring (7) over the armature shaft and press
on the armature bearings (4) and (8).
2
Push the bearing sleeve (3) over the ar-
mature bearing (4).
3
Lightly grease the armature bearing (8)
and insert the complete armature into the
machine by turning it.
4
Insert the brush holders (C) into the motor
housing (9). Align them with the adjust-
ment tool (service tool) and fix them with
the screws (B).
5
Push the field (1) into the motor hous-
ing (9) and insert the air deflector ring (2).
Mind the right position!
6
Push the motor housing (9) with the
field (1) and the air deflector ring (2) over
the armature.
7
Fasten the motor housing with two short
screws (A) and two long screws (D).
Repair Instructions No.181.03/98
2
1
h
i
j
k
PHE 6 H / PHE 6 S
3
7 6
8
9
8
7
6
5
4
3
C
2
1
D
C
PAGE
15
4
5
11
12
9
A
B