4.1 Introduction
This section provides instructions for installing the FreeSpace
E-4 system hardware on a tabletop or in a rack.
4.2 Included accessories
The following accessories are shipped with the E-4 unit in the
FreeSpace E-4 System Accessory Kit (PC030105).
• 2-terminal input connectors (6) – For wiring
Auto Volume mics to the
SENSE MICROPHONES jacks
• 3-terminal input connectors (2) – For wiring
equipment to the AUX MIC/LINE 3 jacks
• 4-terminal input connectors (3) – For wiring
equipment to the ZONE 4 LINE OUT,
PAGE/MIC/LINE 4, and
DIRECT IN/CONTROL jacks
• 2-terminal output connectors (5) – For wir-
ing speaker cables to the ZONE OUT jacks
• Rubber feet (4) – For installing the E-4 unit
on a level surface
• Replacement voltage label (2) – Used on
the OUTPUT VOLTAGE selection switch
• FreeSpace system Installer™
software CD – Contains application
software for programming the E-4
system
4.0 Hardware Installation
®
25 of 76
4.3 Placement guidelines
• Place the E-4 unit where it is protected from heat and allowed
adequate ventilation.
• Place the E-4 unit away from direct heat sources, such as heat-
ing vents and radiators.
• Make sure that air can circulate freely behind, beside, and
above the unit. Allow six inches on all sides.
Installer's Note: Do not allow the chassis to exceed the
maximum operating temperature of 50˚ C (122˚ F). Be aware
of conditions in an enclosed rack that may increase the tem-
perature above room-ambient conditions.
4.4 Shelf mounting the E-4 unit
The E-4 unit is ideal for shelf mounting. The included accessory
kit contains four rubber feet for the bottom of the E-4 chassis.
The rubber feet will protect the surface on which the E-4 unit is
installed and help prevent movement of the E-4 unit. Be sure to
follow the "Placement Guidelines" previously described when
choosing a location for the E-4 unit.