Anpat Electric LINEAR II Manual de instrucciones

Navegue en línea o descargue pdf Manual de instrucciones para Cargador de batería Anpat Electric LINEAR II. Anpat Electric LINEAR II 3 páginas.

OPERATING INSTRUCTIONS MANUAL
PLEASE, READ ALL SAFETY INSTRUCTIONS BEFORE OPERATING THIS UNIT
INTRODUCTION:
The Linear II Battery Chargers are fully automatic.
microprocessor controlled. The output is current limited for the protection of your equipment.
The following input/output specifications are subject to change due to design improvements:
OPERATION:
Always connect the battery charger to the battery prior to connecting to the
A/C source.
1) When the charger is plugged into an AC source, either 115, 208 or 220 volts 60 or 50 Hz, the
microprocessor will turn the charger on, after a 5 to 8 second diagnostic delay the green LED
will illuminate. This delay eliminates any output spike from the charger on the initiation of
charge.
The Green LED flashes rapidly while charging. It stops flashing when charge is completed
and stays on as a solid green light.
2) When the battery voltage reaches the 80% CHARGED level a the Yellow LED light will
illuminate.
3) The microprocessor continuously monitors the battery voltage and automatically adjusts for
the optimal finishing charge.
4) If the Red CHECK BATTERY light illuminates, this indicates a problem with the battery.
Possible causes: A. The battery has not reached the end of the first stage of the operation
within 16 hours. Check the battery for proper connections, possible battery internal failure.
B.The battery A/H capacity is too large for the charger's output rating.
Actions to be taken:
Disconnect the charger from the A/C and wait a moment, reconnect the A/C to the charger. If
the charger begins charging again this may indicate that the A/H rating of the batteries
exceeds the charger's rated output.
5) If the battery-operated vehicle is in storage for extended periods and the charger is connected
to a reliable AC source, the charger will reinitiate the charge cycle when the battery voltage
drops below a predetermined level as specified via programming.
6) When disconnecting the battery charger always disconnect the A/C before
disconnecting the battery.
www.chargersdirect.com / Email: [email protected] / Fax: 310.638.5024
10/09/06 Linear II Oper Inst
Anpat Electric Mfg. LLC
IPD
International Power Devices
LINEAR II BATTERY CHARGERS
Call Toll Free 800.775.5310
The input and output of the charger is