DSC LCD5501Z Manual de instrucciones de instalación - Página 6

Navegue en línea o descargue pdf Manual de instrucciones de instalación para Teclado DSC LCD5501Z. DSC LCD5501Z 12 páginas. Dsc keypad
También para DSC LCD5501Z: Utilizando (4 páginas)

DSC LCD5501Z Manual de instrucciones de instalación
Alarms Displayed While Armed Option
You can disable the display of alarms on the
keypad when the system is armed. The display
of alarms is enabled by default. To disable the
display of alarms when the system is armed, turn
off section [6], option [5]:
1. Enter [*][8][Installer's code]
2. Enter [000] to go to keypad programming
3. To turn the display of alarms on or off, enter
section [6].
4. Turn option [5] on or off:
[5] ON = Alarms not displayed while system
is armed
OFF = Alarms are always displayed
while system is armed
5. When you are finished, press [#] to exit.
Emergency (Fire, Auxiliary, Panic) Key
Options
You can enable or disable the Fire, Auxiliary and
Panic keys at each keypad. These keys are
enabled by default. Please see your system's
Installation Manual for more information on these
keys and their options. To turn any of the
emergency keys on or off on the keypad:
1. Enter [*][8][Installer's code]
2. Enter [000] to go to keypad programming
3. Enter section [7].
4. To turn the emergency key options on or off,
press [1], [2], or [3]:
[1] ON = Fire key enabled
OFF = Fire key disabled
[2] ON = Auxiliary key enabled
OFF = Auxiliary key disabled
[3] ON = Panic key enabled
OFF = Panic key disabled
5. When you are finished, press [#] to exit.
6
Door Chime Options
You can program the LCD5501Z keypad to
sound a tone when any zone is opened or
closed. There are two parts to the LCD5501Z
door chime programming:
• Program if the LCD5501Z will chime when zones
are opened and/or closed.
• Program the type of sound the LCD5501Z will
make when an individual zone is opened or closed.
For the door chime feature to work, you will also
need to turn on the Door Chime attribute for
each zone that will trigger the chime. This
programming is done in the control panel
software. Refer to your control panel's Installation
Manual for more information.
Door Chime on Zone Openings/Closings
You can program each LCD5501Z keypad to
sound a door chime when zones are opened and/
or when they are closed. By default, LCD5501Z
keypads are programmed to sound door chimes
on both zone openings and closings.
To change the door chime opening/closing
settings, at each LCD5501Z keypad:
1. Enter [*][8][Installer's code]
2. Enter [000] to go to keypad programming
3. Enter section [6].
4. To turn the options on or off, press [6] or [7]:
[6] ON =
Door Chime Enabled for Zone
Openings
OFF = Door Chime Disabled for Zone
Openings
[7] ON =
Door Chime Enabled for Zone
Closings
OFF = Door Chime Disabled for Zone
Closings
5. When you are finished, press [#] to exit.