Abt Powerline SC6-12 Manual del producto - Página 8

Navegue en línea o descargue pdf Manual del producto para Accesorios para cámaras Abt Powerline SC6-12. Abt Powerline SC6-12 15 páginas. Valve-regulated sealed lead acid battery

TERMINAL
INTERNAL
RESISTANCE
VOLTAGE
Ω
(m )
(V)
13.0
120
110
12.0
100
80
70
11.0
06
60
50
10.0
40
30
20
9.0
10
0
0
2

Charge

Correct charging is one of the most important
factors to consider when using valve regulated lead
acid batteries. Battery performance and service life
will be directly affected by the efficiency of the
charger selected. The basic charging methods are:
Constant Voltage Charging
Constant Current Charging
Two Stage Constant Voltage Charging
Constant Voltage Charging
Charging at constant voltage is the most suitable
and commonly used method for charging valve
regulated lead acid batteries. Figures 8 - 13 show
the charging characteristics of Powerline SC when
charged by constant voltage chargers at 2.275
volts/cell, 2.40 volts/cell and 2.50 volts/cell when
the initial charging current is controlled at 0.1C
Amps and 0.25C Amps.
Figure 7 shows one example of a constant voltage
charging circuit. In this circuit, the initial charging
current is limited by the series resistance R1.
Figure 7. One example of constant voltage
chargeine circuit
T
AC
Note
The recommended float charge voltage for
Powerline SC at 20 C is 2.275vpc ±0.005v. this
should be the measured average for the total
battery, however when measured within a battery
network or string the allowable tolerances can be
expected between 2.25vpc to 2.30vpc.
BATTERY:SC12-7
AMBIENT TEMPERATURE:20 C(68 F)
MEASURED WITH 1000H AC BRIDGE
10Hr
3Hr
5Hr
4
6
8
10
12
14
16
DISCHARGE TIME(HOUSE)
D
R
2
TR
1
1
D
1
R
5
11
10 2
3
12
4
R
IC
2
6
VR
13
5
C
7
C
R
2
R
1
4
3
o
Figure 8. Charging characteristics
o
o
(%) (xCA) (V)
Z
120
100
7.50
0.1
80
7.00
0.08
60
20Hr
6.50
0.06
40
6.00
0.04
20
0.02
5.50
0
0
18
20
22
Figure9. Charging characteristics
(%) (xCA)
(V)
140
120
7.50
100
7.00
80
0.1
0.08
6.50
60
0.06
40
6.00
0.04
20
0.02
5.50
0
0
0
Figure10. Charging characteristics
(%) (xCA)
(V)
140
120
7.50
100
7.00
0.1
80
0.08
6.50
60
0.06
40
6.00
0.04
20
0.02
5.50
0
0
LOAD
Batt.
Figure 11. Charging characteristics
(%)
(xCA)
140
0.25
120
7.50
100
0.20
7.00
80
0.15
6.50
60
0.10
40
6.00
0.05
20
5.50
0
0
0.1CA-6.825V(13.65V,4.55V)CONSTANT VOLTAGE
CHARGING AT20 C(68 F)
CHARGE VOLTAGE
AFTER 100% DISCHARGE
AFTER 50% DISCHARGE
CHARGING CURRENT
0
5
10
15
20
25
30
CHARGING TIME (HOUSE)
0.1CA - 7.20V(14.4V,4.8V) CONSTANT VOLTAGE
CHARGINGAT 20 C (68 F)
CHARGE VOLTAGE
AFTER 100% DISCHARGE
AFTER 50% DISCHARGE
2
4
6
8
10
12
14
CHARGING TIME (HOURS)
0.1CA - 7.50V(15.0V,5.0V) CONSTANT VOLTAGE CHARGING
CHARGE VOLTAGE
AFTER 100% DISCHARGE
AFTER 50% DISCHARGE
CHARGING CURRENT
0
2
4
6
8
10
12
14
CHARGING TIME (HOURS)
0.25CA-6.825V(13.65V,4.55V)CONSTANT
VOLTAGE CHARGING AT20 C(68 F)
(V)
CHARGED VOLUME
CHARGE VOLTAGE
AFTER 100% DISCHARGE
AFTER 50% DISCHARGE
CHARGING CURRENT
0
2
4
6
8
10
12
14
CHARGING TIME (HOUSE)
o
o
(V)
14.0
4.50
13.0
12.0
4.00
11.0
3.50
35
40
o
o
(V)
5.00
15.0
14.0
4.50
13.0
4.00
12.0
11.0
3.50
16
18
20
o
o
AT 20 C (68 F)
(V)
5.00
15.0
14.0
4.50
13.0
12.0
4.00
11.0
3.50
16
18
20
o
o
(V)
15.0
5.00
14.0
4.50
13.0
12.0
4.00
11.0
3.50
16
18
20