Apollo RoadRunner Manual de instalación - Página 9
Navegue en línea o descargue pdf Manual de instalación para Sensores de seguridad Apollo RoadRunner. Apollo RoadRunner 17 páginas. Mobile digital video recording system
También para Apollo RoadRunner: Ser Manual Y Manual De Instrucciones (19 páginas), Manual de instalación (17 páginas), Manual de usuario y manual de instrucciones (11 páginas)
1331-118th Ave SE, Ste 300 - Bellevue, WA 98005
Tel: 425.453.0430 / Fax: 425.453.0959
www.avt-usa.com
It may be necessary or preferable to use switches, doors or other triggers to initiate recording.
STOP
Any 12 VDC or higher ouput MUST use
the supplied relay or damage to the DVR
can result.
Devices which go to Ground when
activated do not require the relay and
may be connected directly to the DVR
alarm inputs.
Many devices besides door switches or
indicators may be used as recording and
event log triggers.
Up to three external devices can be used
as Recording and Event log triggers.
Some software set-up is required; see
RoadRunner manual for more information.
Alarm input 4 is reserved for the optional
Panic Button.
READ THE FOLLOWING PRIOR TO INSTALLATION
Relay Connections:
85
From 12 VDC trigger
86
To DVR alarm ground
30
Tied to 86
87
To DVR alarm input 1, 2 or 3
RoadRunner Installation Guide
Connections: External Recording Triggers
87
From 12 VDC output
85
30
To DVR alarm ground input
To DVR alarm input 1, 2 or 3
Supplied Relays
and connectors
86
Page 8