Datalogic Compact 2D Reader Matrix-2000 Manual de consulta rápida - Página 7

Navegue en línea o descargue pdf Manual de consulta rápida para Lector de códigos de barras Datalogic Compact 2D Reader Matrix-2000. Datalogic Compact 2D Reader Matrix-2000 11 páginas.

Input / Output Connections:
Inputs
MATRIX
30 Vdc Max.
A
V
CC
~
-
+
~
B
Input PNP command using external power
MATRIX
VS
A
V
CC
~
-
+
~
B
Input NPN command using external power
The electrical features of the two inputs are:
INPUT
Open
Closed
Outputs
MATRIX
+
-
Open collector output connection
Vext
USER INTERFACE
+
V
OUT
I
in
GND
USER INTERFACE
Vext
30 Vdc Max.
+
V
OUT
GND
| V
| Min.
AB
0 V
4.5 V
USER INTERFACE
Vext 30 Vdc max
V
I
Out
Load
MATRIX-2000™ QUICK GUIDE
MATRIX
VS
9
A
V
CC
~
-
+
~
B
GND
25
Input PNP command using Matrix-2000    power
MATRIX
VS
9
A
V
CC
~
-
+
~
B
GND
25
Input NPN command using Matrix-2000    power
| V
| Max.
I
AB
2 V
0 mA
30 V
10 mA
The electrical features of the three outputs are the
following:
OUTPUT
I
Open
0 mA
Closed
10 mA
× I
P
= V
= 170 mW Max.
D
out
load
USER INTERFACE
+
V
OUT
GND
USER INTERFACE
+
V
OUT
GND
Max
IN
.
V
Load
Out
30 Vdc Max
1.8 Vdc Max
7