Dataprobe K-410 Manual - Página 5

Navegue en línea o descargue pdf Manual para Regletas de enchufes Dataprobe K-410. Dataprobe K-410 6 páginas. Remote control

Series K-x20, K-x15 & K-x10

SPECIFICATIONS

Physical
19" wide x 6.25" deep x 1.75" high, EIA Rack Mount -1RU
Weight: 5 Lbs.
INDICATORS:
Power
Model K-820 & K-420
Model K-815 & K-415
Model K-810 & K-410
Power Connections
K-820 & K-420
Main Power Input:
NEMA 5-20 Plug on 6 foot 12/3 line cord
Output Circuits:
Standard NEMA 5-15 Receptacle
Current Maximums:
12 Amps per Receptacle
16 Amps combined total of all receptacles
K-815 & K-415
Main Power Input:
Standard NEMA 5-15 Plug on 6 foot 14/3 line cord - 120VAC
Output Circuits:
Standard NEMA 5-15 Receptacle
Current Maximums:
12 Amps per Receptacle
12 Amps combined total of all receptacles
K-810 & K-410
Select the proper voltage, 115V or 230 V, using the selector switch on the side of the unit before
making power connection
Main Power Input:
IEC 320 Male Connector - 115/230 VAC Selectable
Output Circuits:
IEC 320 Receptacle
Current Maximums:
12 Amps per Receptacle @ 115VAC
10 Amps per Receptacle @ 230VAC
12 Amps combined total of all receptacles @ 115VAC
10 Amps combined total of all receptacles @ 230VAC
Power : On = Power applied to the unit
1 - 8
On = Power on to outlet specified
110 -120VAC 60 Hz, 16A Max
110 -120VAC 60 Hz, 12A Max
Switch Selectable ;110-120VAC 50-60Hz, 12A Max
210-240VAC 50-60 Hz, 10A Max
Page 5
C
R