TO THE INSTALLER
TABLE 1. installation Guide For Fresnei Lenses
Regular maintenance and Inspection (at least annually) by the installer and
frequent testing by the user are vltal to continuous satisfactory operation
of any alarm system.
The mstaller should assume the responslblllty of developing and offering
a regular maintenance program to the user, as well as acquainting the user
with the proper operation and IImItatIons of the alarm system and Its
Component parts. Recommendations must be included for a specific
program of frequent testing (at least weekly) to insure the system's
operation at all times.
Part
No.
Description/
Coverage
Pulse
Count
Setting
Recommended
Mounting
Height (Ft)
Recommended
Sensitivity
Setting'
(See Note Below)
SPECIFICATIONS
Detection Method:
Passive Infrared.
Coverage:
No. 1990 (Dual)
No. 1992 (Quad)
(with standard
60 II x 60 ft, 90"
50 ft x 60 ft, 90
Fresnel Lens)
(18 3m x 18.3m)
(15 2m x 18.3m)
For Interchangeable
optlonal Fresnel lenses, see Table 1.
Detection Zones:
I8 zones (9 long, 5 Intermediate. and 4 short range)
Pulse Count:
Installer-selectable,
l-, 2-, or 3-event
Detectable Walk Rate:
05-Sftisec
(.15-1.5misec).
Mounting Height:
7ff nommal (2.1 m)
Indicator:
Red LED with enable/disable
link.
Alarm Relay:
No. 7990
No. 7992
Form A, N.C ,
Form C, SPDT,
0.13A max. contact
1 A@ 30V DC
rating @ 28V DC.
A
STANDARD WIDE
ANGLE LENS
60' x 60' (1990)
(18Mx18M)
50' x 60' (1992)
(15Mx 18M)
2 - 3"
7(2.1M)
D PI
G (Q)
A
199PA
-
OPTIONAL FRESNEL LENSES -
PET ALLEY LENS
60' x 90' (1990)
(18Mx27M)
50' x 70' (1992)
(15M x 21.3M)
2 - 3**
3 - 3.5
(0.9M - 1 .l M)
D (D)
G (Q)
A199LR
-
LONG RANGE LENS
12O'x12'
(36.5M x3.6M)
(1990 & 1992)
1 -2"'"
6 (1.8M)
D PI
G (Q)
Input Voltage:
Current Drain:
Standby Capability:
Operating
Temperature:
Operating Humidity:
Dimensions:
22-ohm Internal; reststor In series.
12 VDC nominal (voltage reversal makes
PIR InoperatIve).
15 mA.
Power source should be capable of at least
4 hours of battery standby.
No 7990
No. 7992
32°F - 122°F
14°F - 122°F
(0°F - 50°C)
(-10°C - 50°C)
Up to 95% RH (max.), non-condensing
*
2-11MW x 43/4"H x 17/a"D; (68mm x 120mm x 48mm).
'UL tested to 85% RH.
199HL
HALLgWRAOYdFT)
70' x 70' (1990)
(21.3M x21.3Mj
7O'x60'(1992)
(21.3M x 18.3M)
HALLr;AY&;GHT)
70' x 70' I1 9901
1 -
2-9
7 (2.2M)
D 03
G (Q)
-
199HR
(21.3M x 21 .3ti)
1 -
2"'
7 (2.2M)
?'O'x60' (1992j
(21.3M x 18.3M)
HALLWAY &
2 ROOMS
80' x 70' (1990)
(24.3M x 21.3M)
75'x65' (1992)
(23M x 20M)
D (0)
G (Q)
199H2R
1 -
2***
7 (2.2M)
Pattern
Setting
Deg)t
Correction (in ") per Ft
if not mounted at
Recommended Height
(Pattern Up or Down)*
Mom ting
Height
Pattern
Correction
-5"(D)
* (Q)
Higher:
Lower:
Down 1 "lfl
(1"/30cm)
up
iom
(1"/30cm)
D 07
G (Q)
D (D)
G (0)
+2"(D)
Higher:
Down 1"lft
0"
(Q)
Lower:
g;ft;y'
(1"/30cm~
199WD
SUPER WIDE LENS
5O'x90'(1990)
(15.2M x 27M)
45' x 80' (1992)
(13.7M x 24.3M)
THE LIMITATIONS OF YOUR PASSIVE INFRARED MOTION DETECTOR
While the Intrusion Detector is a highly reliable intrusion detection
device, it does not offer guaranteed protection against burglary. Any
Intrusion Detection device is subject to compromise or failure to
warn for a variety of reasons:
l
Passive Infrared Motion Detectors can only detect intrusion within
the designed ranges as diagrammed in this installation manual.
l
Passive Infrared Motion Detectors do not provide volumetric area
protection. They do create multiple beams of protection, and intru-
sion can only be detected in unobstructed areas covered by those
beams.
l
Passive Infrared Detectors cannot detect motion or intrusion that
takes place behind walls, ceilings, floors, closed doors, glass par-
titions, glass doors, or windows.
l
Mechanical tampering, masking, painting or spraying of any mat-
erial on the lenses, windows or any part of the optical system can
reduce the detection ability of the Passive Infrared Motion Detector.
l
Passive Infrared Detectors sense changes in temperature; how-
ever, as the ambient temperature of the protected area ap-
proaches the temperature range of 90" to 105°F (32" to 40" C),
the detection performance can decrease.
l
This Passive Infrared Detector will not operate without appropriate
DC power connected to it, or if the DC power is improperly con-
nected (i.e., reversed polarity connections).
l
Passive Infrared Detectors, like other electrical devices, are subject
to component failure. Even though this equipment is designed to
last as long as 10 years, the electronic components in it could fail
at any time.
We have cited some of the most common reasons that a Passive
Infrared Motion Detector can fail to catch intrusion. However, this
does not imply that these are the only reasons, and therefore it is
recommended that weekly testing of this type of unit, in conjunction
with weekly testing of the entire alarm system, be performed to
ensure that the detectors are working properly.
Installing an alarm system may make the owner eligible for lower
insurance rates, but an alarm system is not a substitute for insurance.
Homeowners, property owners and renters should continue to act
prudently in protecting themselves and continue to insure their lives
and property.
We continue to develop new and improved protection devices. Users
of alarm systems owe it to themselves and their loved ones to learn
about these developments.
-
7 (2.2M)
2 - 3**
NOTE: A mounting height greater than 12 Ft. is not recommended.
(D) = Dual (1990; (Q) = Quad
(1992)
See Figure 5 for location of adjustment scale on PC board (refer also to "E. Vertical Pattern Adjustment")
The sensitivity settings may be reduced from those recommended above to eliminate potential sources of false alarms that cannot be corrected
by lens masking or PIR positioning. To reduce sensitivity, rotate sensitivity control counter-clockwise. However, settings may be reduced (from
those recommended) only when the PIR is used in a temperature-controlled environment where the temperature does not exceed 75°F (24°C).
if the PIR is to operate in high ambient temperatures, the sensitivity control may be increased (clockwise rotation) as required. The protected
area must always be walk-tested after any sensitivity adjustment is made.
The 3-event pulse count setting provides maximum protection against false alarms caused by environmental disturbances. It may be programmed
for wide angle lens applications only when range of the protected area is no greater than 30 ft (approx. 9m).
l *
l
** Normally set for 1 -event pulse count. 2-event pulse count setting may be used if you are assured that the intruder path will cross left and right
fields of view on the long range protective zone.
A
Nos. 1990 and 1992 are UL Listed for use with these lenses only.
Example of the use of Table 1:
Lens 199PA is installed in No. 1990 which is mounted at a height of 4.5 feet (1 ft higher than recommended).
From Table 1, settings for No. 1990 (D) are as follows: Pulse Count setting is 2 or 3, Sensitivity setting is position D, Pattern setting is + lo (down
lo from + 2" shown for recommended height of 3.5 ft).
PROTECTION PATTERNS FOR OPTIONAL LENSES
TOP VIEW
199PA
TOP VIEW
SIDE VIEW
199LR
112 Ft.
0
20 Ft.
40 Ft.
60 Ft.
80 Ft.
100 Ft. 120 Ft.
(6m)
(12m)
(16m)
(24m)
(30m)
(36m)
SIDE VIEW
,-&,
0
loll.
2Oft. 3Ott 4011 501. 60k.
(3m)
(6m) (9m) (12m) (15m) (lsm)
TOP VIEW
LIMITED WARRANTY
Alarm Device Manufacturing Company, a Division of Pimay Corpor-
ation, and its divisions, subsidiaries and affiliates ("Seller"), 165
Eileen Way, Syosset, New York 11791, warrants its products to be
in conformance with its own plans and specifications and to be free
from defects in materials and workmanship under normal use and
service for 18 months from the date stamp control on the product
or, for products not having an Ademco date stamp, for 12 months
from date of original purchase unless installation instructions or
catalog sets forth a shorter period, in which case the shorter period
shall apply. Seller's obligation shall be limited to repairing or replac-
ing, at its option, free of charge for materials or labor, any part which
is proved not in compliance with Seller's specifications or proves
defective in materials or workmanship under normal use and service.
Seller shall have no obligation under this Limited Warranty or other-
wise if the product is altered or improperly repaired or serviced by
anyone other than the Ademco factory service. For warranty service,
return product transporation prepaid, to Ademco Factory Service,
165 Eileen Way, Syosset, New York 11791.
THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, OF
MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PUR-
POSE OR OTHERWISE, WHICH EXTEND BEYOND THE DE-
SCRIPTION ON THE FACE HEREOF. IN NO CASE SHALL SEL-
LER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR
INCIDENTAL
DAMAGES
FOR BREACH OF THIS OR ANY
OTHER WARRANTY, EXPRESS OR IMPLIED, OR UPON ANY
OTHER BASIS OF LIABILITY WHATSOEVER, EVEN IF THE
LOSS OR DAMAGE IS CAUSED BY THE SELLER'S OWN NEG-
LIGENCE OR FAULT.
Seller does not represent that its product may not be compromised
or circumvented; that the product will prevent any personal injury
or property loss by burglary, robbery, fire or otherwise; or that the
product will in all cases provide adequate warning or protection.
Buyer understands that a properly installed and maintained alarm
may only reduce the risk of a burglary, robbery or fire without warn-
ing, but it is not insurance or a guarantee that such will not occur
or that there will be no personal injury or property loss as a result.
CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR
ANY PERSONAL INJURY, PROPERTY DAMAGE OR OTHER
LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE
WARNING. However, if Seller is held liable, whether directly or
indirectly, for any loss or damage arising under this Limited Warranty
or otherwise, regardless of cause or origin, Seller's maximum liability
shall not in any case exceed the purchase price of the product,
which shall be the complete and exclusive remedy against Seller.
This warranty replaces any previous warranties and is the only
warranty made by Seller on this product. No increase or alteration,
written or verbal, of the obligation of this Limited Warranty is
authorized.
ALARM
DEVICE
MANUFACTURING
CO.
A DIVISION OF Pill-WAY
CORPORATION
165 Eileen Way, Syosset, New York 11791
Copyright @ 1990 PIllWAY CORPORATION
N4673-1 Dl
8190
199HL
(Room Zones Only)
TOP VIEW
199HR
90'
SIDE VIEW
!
I I
.
Quad Limit
: (Room Zones Only)
/
SIDE VIEW
TOP VIEW
TOP VIEW
199H2R
/
45n.
Ouad Llmlt
(Intemwdlate)
75n.
Quad Llmil
(Low)
I
SIDE VIEW
I
(C~&~)
45ft.
(13.7m)
SIDE VIEW
i
I
7n
em)
- _.____.__ -
---