DBI SALA Sealed-Blok 3400968 Manual de instrucciones - Página 9
Navegue en línea o descargue pdf Manual de instrucciones para Equipos de seguridad DBI SALA Sealed-Blok 3400968. DBI SALA Sealed-Blok 3400968 17 páginas. Self retracting lifelines
IMPACT INDICATOR: To inspect the impact indicator, look for exposed
color band on hook as shown in Figure 7. If the hook is in the "indicated
mode," an impact loading has occurred. SRLs which have been subjected
to impact loading must be removed from service for inspection. Do not
attempt to reset impact indicator. Return to an authorized service center
for resetting.
NOTE: Swivel will not turn freely in "indicated mode."
WIRE ROPE: Inspect wire rope for cuts, kinks,
broken wires, bird-caging, welding splatter, corrosion,
chemical contact areas, or severely abraded areas.
Slide the cable bumper up and inspect ferrules for
cracks or damage and inspect the wire rope for
corrosion and broken wires.
NOTE: Replace the wire rope assembly if there are
six or more randomly distributed broken wires in
one lay, or three or more broken wires in one strand
in one lay. A "lay" of wire rope is the length of wire
rope it takes for a strand (the larger groups of wires)
to complete one revolution or twist along the rope.
Replace the wire rope assembly if there are any
broken wires within 1 inch (25mm) of the ferrules.
WARNING: Do not tie or knot lifeline. Avoid lifeline contact with sharp or abrasive surfaces. Inspect lifeline
frequently for cuts, fraying, burns, or signs of chemical damage. Dirt, contaminants, and water can lower
dielectric properties of the lifeline. Use caution near power lines.
Inspect each system component or subsystem according to manufacturer's instructions.
Record inspection results in the inspection log found in section 9.0.
5.3
UNSAFE OR DEFECTIVE CONDITIONS: If inspection reveals an unsafe or defective condition, remove the
Sealed-Blok™ SRL from service immediately and contact an authorized service center for repair.
NOTE: Only Capital Safety or parties authorized in writing may make repairs to this equipment. (Excludes
FAST-Line
procedure).
TM
5.4
I-SAFE™ RFID TAG: The Sealed-Blok™
Self Retracting Lifeline includes an i-Safe™
Radio Frequency Identifi cation (RFID) tag.
The RFID tag can be used in conjunction
with the i-Safe handheld reading device and
web based portal to simplify inspection and
inventory control and provide records for your
fall protection equipment. If you are a fi rst-time
user, contact a Capital Safety Customer Service
representative (see back cover); or if you have
already registered, go to www.capitalsafety.
com/isafe.html. Follow the instructions provided
with your i-Safe handheld reader or on the web
portal to transfer your data to your web log.
netzerotools.com
netzerotools.com
Figure 7 - Impact Indicator
Figure 8 - Lifeline Damage
Kinked wire rope
Broken wires
Bird-caging
Welding splatter
Figure 9 - i-Safe™ RFID Tag
8
netzerotools.com
netzerotools.com