Autonics ARD-A Series Manual - Página 2
Navegue en línea o descargue pdf Manual para Sistemas de E/S Autonics ARD-A Series. Autonics ARD-A Series 10 páginas. Devicenet remote i/o analog, terminal block type
También para Autonics ARD-A Series: Manual del producto (4 páginas)
Specifications
ARD-AI04
Model
Power supply
Rated voltage: 24VDCᜡ, Voltage range: 12-28VDCᜡ
Power consumption
Max. 3W
Input 4-point
I/O points
(switchable voltage/current)
0-10VDCᜡ, -10-10VDCᜡ, 0-5VDCᜡ, 1-5VDCᜡ,
Voltage
-5-5VDCᜡ (input impedance: max. 1MΩ)
Current
DC4-20mA, DC0-20mA (input impedance: 250Ω)
Control
I/O
Max. allowable range ±5% F.S of rated input range
Resolution
14bit, 1/16,000
Accuracy
● At room temperature (25±5℃) range: ±0.3% F.S.
Insulation resistance
Over 200MΩ (at 500VDC megger)
Noise immunity
±240V the square wave noise (pulse width: 1㎲) by the noise simulator
Dielectric strength
500VAC 50/60Hz for 1 min (between external terminals and case, between I/O and power terminals)
Vibration
1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours
Shock
500m/s
Ambient
-10 to 50℃, storage: -25 to 75℃
temperature
Environ-
ment
Ambient
35 to 85%RH, storage: 35 to 85%RH
humidity
Protection structure
IP20 (IEC standard)
Protection circuit
Surge, ESD protection, reverse polarity protection circuit
Indicator
Network status (NS) LED (green, red), unit status (MS) LED (green, red)
Material
Front case, body case: Polycarbonate
Mounting
DIN rail or bolt mounting type
Isolation type
I/O and inner circuit: non-insulated, DeviceNet and inner circuit: insulated, power and DeviceNet: insulated
Approval
※ 1
Weight
Approx. 210g (approx. 145g)
※ Environment resistance is rated at no freezing or condensation.
※ 1. The weight includes packaging. The weight in parentheses is for unit only.
DeviceNet Communication
Item
Specifications
I/O Slave messaging (Group 2 Only slave)
Communication
● Poll command: Yes
Communication distance
Max. 500m (125kbps), Max. 250m (250kbps), Max. 100m (500kbps)
NODE ADDRESS setting
Max. 64 nodes
※ 1
Communication speed
125, 250, 500kbps (automatically set when connecting with Master)
Insulation
I/O and inner circuit: Non-insulation, DeviceNetand inner circuit: Insulation, DeviceNet power: Insulation
ODVA Conformance conformance: ARD-AI04
Approval
ODVA Conformance compatible : ARD-AO04
※ 1. The communication speed is automatically set to the communication speed of the Master (PC, PLC, etc.) When changing the
communication speed during operation, the network status (NS) LED flashes in red and communication is not possible.
DeviceNet Analog Remote I/O
2
(approx. 50 G) in each X, Y, Z direction for 3 times
● Bit_strobe command: Yes ● Cyclic command: Yes ● COS command: Yes
ARD-AO04
Output 4-point
(voltage 2CH, current 2CH)
0-10VDCᜡ, -10-10VDCᜡ, 0-5VDCᜡ, 1-5VDCᜡ,
-5-5VDCᜡ (load resistance: max. 1kΩ)
DC4-20mA, DC0-20mA (load resistance: max. 600Ω)
±5% F.S of rated output range
● Out of room temperature range: ±0.6% F.S.
, DeviceNet compatible
SENSORS
CONTROLLERS
MOTION DEVICES
SOFTWARE
(J)
Temperature
Controllers
(K)
SSRs
(L)
Power
Controllers
(M)
Counters
(N)
Timers
(O)
Digital
Panel Meters
(P)
Indicators
(Q)
Converters
(R)
Digital
Display Units
(S)
Sensor
Controllers
(T)
Switching
Mode Power
Supplies
(U)
Recorders
(V)
HMIs
(W)
Panel PC
(X)
Field Network
Devices
X-25