Autonnic A5024 Manual de uso e instalación - Página 8

Navegue en línea o descargue pdf Manual de uso e instalación para Brújula Autonnic A5024. Autonnic A5024 19 páginas. Fluxgate compass

Autonnic A5024 Manual de uso e instalación
2

Connecting the compass to your application

2.1 Compass to a NMEA-0183 instrument
The hardware on which the NMEA-0183 standard is based on is a balanced serial
protocol called RS422. This means that two wires are need for send and two for
receive.
Note that the GND wire is used for the current return path. This might be
shared with the NMEA- wire in some installations.
2.2 Compass to a PC serial port
In many cases the wires can be joined directly as shown in Fig 2.
Alternatively use the Autonnic A3036 serial interface unit.
A 5 0 2 2
Fig 2
+
1 + 8 - 3 0 V
P O W
S O U R C E
7 G N D
5 G N D
3 N M E A I N -
4 N M E A I N +
6 N M E A O U T +
Fig 3
6 NMEA OUT +
5
GND
4 NMEA IN+
+
NMEA current
source
3 NMEA IN-
-
External NMEA device
-
E R
8 of 19
A5023/24
C O M P O R T D
C O N N E C T O R
5
3
2