Operating and maintenance manual
3.3

Maintenance

The alkitronic® torque multipliers are extremely
powerful, robust products. To ensure durability
and performance over many years, regular main-
tenance is required (performance check, engine
check, safety check).
Maintenance periods: Regularly 1x per year or after max.
1000 hours of operation if used properly.
alkitronic® multipliers should only be shipped to your al-
kitronic® Partner or to alki TECHNIK GmbH in the original
packaging to avoid damage.
In the event of prolonged periods without operation, the
motor of the alkitronic® multiplier must be supplied with oil
via the connector (1) of the compressed air supply at the pis-
tol grip (Fig. 8). This prevents corrosion damage to the motor
lamella (see Section 4.1, Air lubrication).
Protect the compressed air supply on the multiplier with a
protective cap to prevent dirt from entering.
4.

Technical details

4.1

Air lubrication

Brand/Type
Properties:
Specification / Use:
(The manufacturer does not guarantee for other brands)
4.2

Noise emission and vibrations

The sound pressure level measured at maximum engine
power exceeds 85 dB (A). The measurements were carried
out in accordance with the noise measurement method DIN
EN ISO 15744: 2008-11.
Vibration: There are no significant vibrations.
alkitronic® torque multipliers with lower sound pressure lev-
els (<85 dB (A)) are available as special versions. When fitting
with silencer elements, the torque characteristics must be
corrected accordingly.
Fig. 8
1
Aral /Vitam DE 10
Resin and acid-free, moisture-
binding, high corrosion- and
wear protection
SAE 10W
Oil viscosity 40°C: -10 cST,
2-3 drops per min. during
continuous operation
5.

Declaration of conformity

alki Technik GmbH declares in sole responsibility: The
alkitronic® pneumatic multipliers identified by types CLS,
CLS 2, CLD, CLV and serial numbers 913001 - 913699, built in
2019, complies with all relevant regulations such as directives /
standards / safety regulations:
2006/42/EG,
DIN EN ISO 12100:2011-03,
DIN EN ISO 4414:2011-04,
DIN EN ISO 13849-2.2013-02,
DIN EN ISO 11148 6:2013-05,
DIN EN ISO 15744:2008-11
Technical Documents at alki TECHNIK GmbH,
Unterlettenweg 4, 85051 Ingolstadt / Germany.
6.

Maintenance unit

Regulator type
Controller function
Pressure supply
Installation position
Ambient temperature
Operating pressure
min./max.
Control range min./max.
Filter element
Container volume Filter
Drain valve
Filling type
Container volume Oiler
Pressure control valve Button for filling the oiler by suction
on the lower part of the container
Connection for oil extraction and filling
Art. No. 20350 - Maintenance unit complete
including 5 m hose, bracket and special oil
10
January 2019
Alexander Kipfelsberger,
Managing Director
diaphragm pressure control valves
with secondary venting
on one side
vertical
min. -10°C /max. +50°C
1.5 bar (21.75 PSI) /
16 bar (232 PSI)
0.5 bar (7.25 PSI) /
8 bar (116 PSI)
exchangeable
49 cm³ / 2.45 inch³
semi-automatic,
depressurised open
manual oil filling
semi-automatic oil filling
during operation
80 cm³/ 4.9 inch³