5.
CAPACITY COMPENSATION RATE FOR PIPE LENGTH
AND HEIGHT DIFFERENCE
This table is created using the maximum capacity.
MODEL
: AOG12LA
COOLING
Indoor unit is
upper than
outdoor unit.
Height
difference H
(m)
Indoor unit is
under than
outdoor unit
HEATING
Indoor unit is
upper than
outdoor unit.
Height
difference H
(m)
Indoor unit is
under than
outdoor unit
Indoor unit
Connection pipe
1 Indoor unit is upper than outdoor unit.
5
15
-
Û 1
10
-
7.5
-
5
1.018
0
1.026
-5
1.026
Û 2
-7.5
-
-10
-
-15
-
5
15
-
Û 1
10
-
7.5
-
5
0.954
0
0.954
-5
0.949
Û 2
-7.5
-
-10
-
-15
-
Height difference H
Outdoor unit
- (02 - 05) -
Pipe length (m)
7.5
10
15
-
-
0.903
-
0.964
0.918
0.988
0.968
0.922
0.992
0.972
0.925
1.000
0.980
0.933
1.000
0.980
0.933
1.000
0.980
0.933
-
0.980
0.933
-
-
0.933
Pipe length (m)
7.5
10
15
-
-
0.943
-
1.010
0.943
1.000
1.010
0.943
1.000
1.010
0.943
1.000
1.010
0.943
0.995
1.005
0.939
0.993
1.002
0.936
-
0.999
0.934
-
-
0.925
Outdoor unit
Indoor unit
Connection pipe
2 Indoor unit is under than outdoor unit.
20
25
0.894
0.867
0.909
0.881
0.912
0.885
0.916
0.888
0.923
0.895
0.923
0.895
0.923
0.895
0.923
0.895
0.923
0.895
20
25
0.916
0.896
0.916
0.896
0.916
0.896
0.916
0.896
0.916
0.896
0.912
0.892
0.909
0.890
0.907
0.887
0.898
0.878