Play the user message for lift identification, if stored in Lift1.
Extend the call by 30 seconds. Can be used repeatedly.
or
Terminate the call.
or
Identification sending for LiftManager
Switch operating keyword for switch must start with this numbers.
,

Before you start

Installation Conditions
·
Lift1 is not intended for outdoor applications.
·
As the product is connected to a telephone line and may thus produce life-endangering voltage,
follow the safety precautions – refer to Safety Precautions.
·
Never connect Lift1 to a line in parallel with another terminal device.
·
Make sure that the lift wall is perfectly flat.
·
Make sure that the lift cabin installation is in compliance with the applicable lift standards.
Tips
·
Use a portable phone to make sure that the telephone line works.
·
Make sure that you know the telephone line number to make a test call.
Mounting
The basic model of Lift1 is designed for mounting to the lift panel from back side. Four 58x122
mm spot-welded M4 screws or other method using the holes in the corner of the device should be
used for fixing. There must be sufficiently perforated speaker area, the perforation may never
exceed the panel size to avoid acoustic fault. There shouldn't be space between the lift panel and
the cabin or the gap must be sealed properly to eliminate acoustic fault of the speaker and
acoustic feedback between the speaker and microphone. In front of the microphone must be the
hole in the panel, recommended diameter is 2 mm or appropriate perforation. When the LED
indicators on the device are used, in front of them must be proper apertures, in this case the
model with lightguides is suggested for better performance.
The cable version of the communicator has the speaker, mike and led indicators connected by
cables, allowing placement according installer needs.
The model with the front panel is necessary to cut out she space in the cabin to insert the unit,
the front panel covers the hole, it is fixed by two screws.
For light indication can be used LED indicators in the unit, external LEDs delivered with the cable
version or indicators build-in by the lift producer. For these external indicators can be used
switches integrated in the device, these switches are electrically separated from the phone line.
External power is in this case necessary.
All described types of Lift1 uses external button Alarm, which is not part of the delivery and must
be connected to the device. Input Cancel can be used for canceling of the activated alarm before
the call is established. Inputs Alarm1 and Cancel can be configured, the positive or negative logic
can be set and electrical separation is available. Input Alarm2 can be used as additional input for
alarm activation or for end of alarm signaling activated by operating personnel.
Details are described in chapter "Mounting" in user manual. Please read carefully the part "Safety
caution" below!