Adapting to different types of gas
It is possible to adapt the appliance to a type of gas
other than the default type (this is indicated on the
rating label on the cover).
Adapting the hob
Replacing the nozzles for the
hob burners:
1. Remove the hob grids and
slide the burners off their seats.
2. Unscrew the nozzles using
a 7 mm socket spanner (see
figure), and replace them with nozzles suited to the
new type of gas (see Burner and nozzle specifications
table).
3. Replace all the components by following the above
instructions in reverse.
Adjusting the hob burners' minimum setting:
1. Turn the tap to the minimum position.
2. Remove the knob and adjust the regulatory screw,
which is positioned inside or next to the tap pin, until
the flame is small but steady.
! If the appliance is connected to a liquid gas supply,
the regulatory screw must be fastened as tightly as
possible.
3. While the burner is alight, quickly change the position of
the knob from minimum to maximum and vice versa several
times, checking that the flame is not extinguished.
The hob burners do not require primary air
adjustment.
!
Adapting the oven
Replacing the oven burner
nozzle:
1. Open the oven door fully
2. Pull out the sliding oven bottom (see diagram).
3. Remove the oven burner
after unscrewing the screws V
(see figure).
V
4. Unscrew the nozzle using a
special nozzle socket spanner
(see figure) or with a 7 mm socket spanner, and
replace it with a new nozzle that is suited to the new
type of gas (see Burner and nozzle specifications table).
Adjusting the gas oven burner's minimum setting:
1. Light the burner (see Start-up and Use).
2. Turn the knob to the minimum position (MIN)
after it has been in the maximum position (MAX) for
approximately 10 minutes.
3. Remove the knob.
4. Tighten or loosen the adjustment screws on the
outside of the thermostat pin (see figure) until the flame
is small but steady.
! In the case of natural gas, the adjustment screw must
be unscrewed by turning it anti-clockwise.
5. Turn the knob from the MAX position to the MIN
position quickly or open and shut
the oven door, making sure that
the burner is not extinguished.