A.H. Systems 2380 Manual del usuario - Página 6
Navegue en línea o descargue pdf Manual del usuario para Antena A.H. Systems 2380. A.H. Systems 2380 14 páginas.
A.H. Systems Model Active Monopole Antennas
OPERATING INSTRUCTIONS
ASSEMBLY INSTRUCTIONS
To prepare the antenna for operation, attach the telescoping rod antenna
element to the top of the high impedance preamplifier. Adjust the rod length to
41" (1.04 meters). Do not operate the Monopole antenna with the Battery
Charger connected.
BATTERY CHARGING INSTRUCTIONS
Position the input voltage selector on the charger to the proper voltage (either
110 – 120 Vac, 60 Hz or 220 – 240 Vac, 50 Hz). Be sure to check the available
voltage and adjust the voltage selector as needed before use. The active
monopole ON-OFF switch must be in the OFF/CHARGE position to charge the
battery. Every hour of charge will result in two hours of operation for up to 10
hours of charging. Charging for up to 24 hours will not damage the battery.
Using the battery charger to operate the amplifier directly is not recommended.
Longest life and best performance can be obtained if the battery is charged
when the air temperature is between 65°F and 75°F (18° - 24°C). DO NOT
charge the battery in an air temperature below 40°F (4.5°C), or above 105°F
(40.5°C).
SETUP INSTRUCTIONS
The active monopole and ground plane can be mounted to any tripod with a
1/4-20 attaching stud. Attach the rod antenna to the connector on the top of the
amplifier. Extend the rod antenna to 41" (104 cm) above the ground plane.
Connect the output BNC connector on the side of the amplifier to the input of a
50 receiver or spectrum analyzer. Establish a ground connection to the
ground plane if required by the test specification.
The POWER indicator LED will illuminate and stay lit as long as the battery has
sufficient voltage to power the active monopole. If the LED does not illuminate,
do not use the active monopole until the battery has been recharged.
© A.H. Systems inc
REV E
6