Anchor Installation: New Construction
NOTE: For installations where a new deck is being poured, or where a dedicated pad is being poured
just for the pool lift, the concrete must satisfy the ADA requirements outlined on page 4 of this manual.
Your pool deck must be at least 4'-0" long by 4'-0" wide by 6" thick. It must be reinforced
with 5 sticks of #5 rebar E-W, 2" clear (min) from the top and bottom of the footing.
1. Remove 1 nut from each anchor insert. Place the anchor inserts through the larger hole
of the anchor jig plate. Thread the removed nuts back onto the anchor inserts. The anchor
plate should be sandwiched between the two nuts on each anchor insert.
SEE FIGURE A, PAGE 6
2. Install rebar in the open area of the deck.
SEE FIGURE B, PAGE 6
3. Set the anchor system in place. Make sure the center of the large anchor jig plate holes
are no more than 19 inches from the pool's edge.
SEE FIGURE C
8-AWG SOLID-COPPER WIRE
(ATTACH TO BONDING-GRID)
BONDING
LUG
48"
2500PSI
DRILL AND EPOXY INTO
EXISTING SLAB (4" MIN)
*SETBACK DIMENSIONS ARE FOR FLAT DECK APPLICATIONS.
FOR SLOPED DECKS OR OTHER FEATURES, CONTACT AQUA
CREEK BEFORE INSTALLATION.
Copyright © 2018 Aqua Creek Products All Rights Reserved
*[37 TO 48cm]
14.50" TO 19"
SETBACK
2.50"
MIN
#5
REBAR
48"
FLUSH WITH DECK
#5 REBAR E-W (5 PCS)
FIGURE C
4. Make sure the top of each
anchor body is fl ush with the
FINISHED deck surface. Each
anchor body can be adjusted
individually by turning the nuts
with a large wrench.
5. Bond the anchoring system
by using the bonding lug on
the anchor jig plate. Bond the
system according to your local
code requirements.
680.26)
POOL
WALL
SEE FIGURE C
6. Pour your concrete and fi nish
the pool deck surface.
SEE FIGURE A, PAGE 6
6"
7. Once the concrete has cured
your lift is ready to be mounted to
the anchoring system.
SEE FIGURE A, PAGE 6
(See NEC Article