Product Manual Omnia Hand Dryer
When making these connections contemplate means for disconnecting from the power grid with a
minimum contact separation of at least 3 mm (0,12") for all poles. These disconnection means must be
incorporated into the fixed installation. The hand dryer must be installed against a solid surface only
(wall, partition, or similar).
The installation, operation and maintenance must be conducted in accordance with the National
Electrical Code, ANSI/NFPA 70 applicable work and safety codes.
AIR TUBE CONNECTION
(A) Route the corrugated tube through the plastic support (10), connect the grounding wire to the
earth tag (11). Make sure the grounding connection is safe and reliable.
(B) Route the IR electrical cables through the adaptor tube (12) cut, placing the gasket in the tube
hole. Close the corrugated tube plastic support (13). Place the clamp in the adaptor tube and con-
nect it to the 'air unit'. Place the adaptor tube as high as possible not forcing the wire. Firmly tight the
clamp.
Check the installation so that the IR sensor cables or the ground are not visible, the corru-
gated tube must completely protect them.
4 of 7
Product Manual Omnia Hand Dryer
IR SENSOR CONNECTION
(A) Route the wire through the plastic support (14) and connect according to B & C.
(B) Connect the IR sensor wire to the electronic board.
(C) Connect the grounding wire to the earth tag (7) make sure the grounding connection is safe and
reliable. Close the corrugated plastic support (15). WARNING: missing of this sequence may impair
grounding connection and safety of the product.
• D) Carefully close the cover, taking care the corrugated tube places on the cover slot.
• (E) Place the washers and the screws for fixing the casing to the base, fixing them tightly us-
ing the special spanner provided.
Revision 01
5 of 7
Revision 01