Aqua Exclusive C-30 PRO Manual del usuario - Página 16

Navegue en línea o descargue pdf Manual del usuario para Sistemas de filtración de agua Aqua Exclusive C-30 PRO. Aqua Exclusive C-30 PRO 20 páginas. Drum filter
También para Aqua Exclusive C-30 PRO: Manual del usuario (18 páginas)

Aqua Exclusive

WATER LEVEL

1. Remove the cover of the housing and check that the float (figure 6) is in the lower position.
(If you are using a pump fed setup you have to reposition the water level sensor, see page
8 and 10 for more information)
2. Open the gate valve on the inlet, and the outlet if present, in order to fill the filter system
with water.
3. Let the filter fill until the correct water level has been reached.
4. Check the water level in the housing.
5. Check all pipes, hoses and connections for leaks.
6. Place the lid back on the housing.
It is important to maintain the correct water level. A lower water level will not make the sys-
tem work properly and higher water levels can cause leaks.
Water level
- Gravity setup: 34,5 cm (13.5")
- Pump fed setup: 32,5 cm (12.8")
Figure 9: Water level C-25 EVO
14
Water Level
C-25 EVO OWNER'S MANUAL