AQUA FORTE SC998 Manual de uso y mantenimiento - Página 14
Navegue en línea o descargue pdf Manual de uso y mantenimiento para Bomba de agua AQUA FORTE SC998. AQUA FORTE SC998 16 páginas. Mini heat pump for swimmingpool
2.6.
Parameter list
Parameter
A
b
c
Inlet water temperature setting value
d
E
F
H
Heat pump restart temperature difference
J
Ambient temperature of antifreeze
O
P
Coil temperature of entering defrosting
U
Coil temperature of exiting defrosting
Inlet water temperature of anti-freezing
t
2.7.
Error code
Malfunction
Inlet water temperature sensor's fault
Coil temperature sensor's fault
Ambient temperature sensor's fault
Super-cooling protection for outlet water
Low pressure protection fault
Water flow protection fault
Defrost
Description
Inlet water temperature
Coil temperature
Ambient temperature
when heating
Interval time of defrosting
Exit time of defrosting
Power off protection
protection
(Reservation)
Range
-19~99 ℃
-19 ~ 99 ℃
-19 ~ 99 ℃
15℃~40℃
10~80Min
5~30Min
1℃~10℃
0~1
0℃~15℃
-19℃~0℃
1℃~30℃
1℃~15℃
Defrosting indicator (Green light)
11
Default Value
Remarks
Measured
Measured
Measured
Adjustable
27℃ (81℉)
Adjustable
40 Min
Adjustable
6 Min
Adjustable
2℃ (4℉)
Adjustable
1(Yes)
Adjustable
5℃(41℉)
Adjustable
-3℃ (27℉)
Adjustable
2℃ (36℉)
Adjustable
4℃
Code
P 1
P 3
P 5
P 7
E 6
E 7