Aqua Medic FB 5000 Manual de instrucciones - Página 4

Navegue en línea o descargue pdf Manual de instrucciones para Acuarios Aqua Medic FB 5000. Aqua Medic FB 5000 12 páginas.
También para Aqua Medic FB 5000: Manual de instrucciones (8 páginas)

Aqua Medic FB 5000 Manual de instrucciones
1. Delivery /Technical data
Delivery: The fluidized bed filter FB 5000 is delivered ready to use, including a filling of filter sand.
A pump is not included.
Technical data:
Dimensions:
Water inlet:
Water outlet:
Bottom drain:
Filter sand filling:
2. Set up and connections
The FB 5000 has to be set up in a way that the outlet water can flow downwards freely, e. g. into
a filter sump. If the water flow is stopped, the check valve prevents that sand enters the inlet pipe.
The water circulation can be made in different ways:
-
As bypass of a larger circulation pump (e. g. a pump from our NK or OK series). This set up is
recommended.
-
With a separate circulation pump. In this case, we recommend Ocean Runner OR 3500.
If the water circulation is made with a bypass of a NK or similar pump, the FB 5000 can be filled
with sand and water before starting. Then the water circulation is started slowly and the sand
starts to fluidize. Very fine particles will be flushed out during the first minutes of operation. If the
water circulation has been shut off for some time and the sand does not start to fluidize by itself,
increase the water flow until the sand starts moving. Then adjust the flow rate until the sand is
moving optimal (see photo page 1).
If the water circulation is done with an Ocean Runner OR 3500, the unit should be filled with water
first. Then switch the circulation on and fill in the sand from above (10 l). Very fine particles will be
flushed out during the first minutes of operation. The height of the fluidized sand should be similar
to the photo on page 1.
If the circulation has been shut off for some time, it may happen that the OR 3500 is not powerful
enough to fluidize the sand again. In this case, connect a hose to the tap water to the bottom drain
and give a short shot of water pressure. This will fluidize the sand and the operation will start
again. A shut off of the circulation for a few minutes is no problem. The pump will manage to
fluidize the sand by itself.
To clean the unit, water and sand can be drained through the bottom drain.
4
reaction pipe 20 cm Ø, height approx. 170 cm
hose connection, ¾"
glue connection DN 40
¾" hose connection
approx. 10 l quartz sand