Operating Your Dehumidifier
lace the dehumidifier in upright position
If the dehumidifier has been laid down in a horizontal position
for any time over a few minutes, you must set it upright
(vertical) for 30 minutes before starting.
Connect the drainage system
You can find the hose wrapped around the back of the
machine. Unwrap the entire hose and run it into a sink, toilet,
drain, or bucket. Remove any kinks in the hose. Use bleach in
the condensate pump once a year to keep clean.
lug in the electrical cord
The electrical cord is stored wrapped around the air outlet on
the back of the unit. Unwrap the cord and plug it into a
standard outlet with the correct voltage and amperage for the
unit. If using an optional 230V to 115V converter that allows
you to plug in multiple units at the same time using your
customers' electric clothes dryer, stove or oven outlet, always
check the voltage with a volt meter.
Before Transporting Your Dehumidifier
Before moving the unit, make sure the pump is empty of water.
llow the unit to sit for 10 minutes after stopping the
dehumidification cycle. Push the PURGE key to clear water.
See "How to Use the Touch Pad Control Panel" for more
details.