Dell EqualLogic PS6110X Manual de hardware - Página 22
Navegue en línea o descargue pdf Manual de hardware para Servidor Dell EqualLogic PS6110X. Dell EqualLogic PS6110X 50 páginas. Equallogic ps series iscsi storage arrays with microsoft windows server failover clusters
Cabling The Dell EqualLogic PS6000/PS6100/PS6500 Storage Arrays
1.
Connect a network cable from the network switch 0 to Ethernet 0 on the control module 1.
2.
Connect a network cable from the network switch 0 to Ethernet 1 on the control module 1.
3.
Connect a network cable from the network switch 1 to Ethernet 2 on the control module 1.
4.
Connect a network cable from the network switch 1 to Ethernet 3 on the control module 1.
5.
Connect a network cable from the network switch 1 to Ethernet 0 on the control module 0.
6.
Connect a network cable from the network switch 1 to Ethernet 1 on the control module 0.
7.
Connect a network cable from the network switch 0 to Ethernet 2 on the control module 0.
8.
Connect a network cable from the network switch 0 to Ethernet 3 on the control module 0.
9.
Repeat steps 1 to 8 to connect the additional Dell EqualLogic PS6000/PS6100/PS6500 storage array(s) to the iSCSI
switches.
NOTE: For PS6100 storage array, having all eight cables in steps 1 through 4 provides highest level of cable
redundancy. It works fine with only four cables. You can skip either step 1 or 5, either step 2 or 6, either step 3 or 7,
and either step 4 or 8.
For more information, see the figures below.
Figure 15. Cabling an iSCSI SAN-Attached Cluster to a Dell EqualLogic PS6000 Storage Array
1. cluster node 1
2. cluster node 2
3. switch 0
4. switch 1
22
5. Dell EqualLogic PS6000 storage system
6. control module 1
7. control module 0