Dell PowerEdge 350 Manual - Página 8
Navegue en línea o descargue pdf Manual para Servidor Dell PowerEdge 350. Dell PowerEdge 350 15 páginas. Wake-on-lan (wol) support on dell servers
También para Dell PowerEdge 350: Actualización de la información de diagnóstico del sistema (2 páginas), Manual de instalación (32 páginas), Información actualizada (30 páginas), Instalación del hardware (22 páginas)
3
Section
Enabling WOL under Microsoft Windows NT
4.0
NICs and LOMs from Dell have WOL disabled by default. Having more than
one device enabled for WOL in a system can overload the 3.3‐volt auxiliary
power supply and cause it to malfunction. Dell strongly recommends that only
one device be enabled for WOL per system. To enable WOL, create a DOS‐
bootable floppy and copy the utility, listed in the Tools section above, specific to
the WOL device to it from the Dell Open Management Server Assistant or
download it from http://support.dell.com.
The steps to enabling WOL under Windows NT 4.0 are as follows:
1. Boot the system using the DOS floppy, and run 'IBAUTIL.EXE',
'UXDIAG.EXE –t ABCD' or 'B57UDIAG.EXE –t ABCD'. These programs will
display the physically installed adapters and the status of each card's WOL
setting. UXDIAG.EXE is for NetXtreme II devices and B57UDIAG.EXE is for
NetXtreme I devices.
2. Choose the NIC for WOL, record its MAC address, and note its number on
the left hand side of the display.
3. Reboot the system and login to Windows NT 4.0 with an account that has
administrator privileges. If the most recent Dell‐provided drivers are not
installed, install them. Dell strongly suggests updating to the newest
versions of the network drivers available on the Dell support web site.
4. For Broadcom NICs and LOMs, or Intel Gigabit (1000 MBps) NICs or LOMs,
skip to step 9.
5. For Intel FastEthernet (10/100 Mbps) NICs or LOMs, from the system tray or
from the control panel, open PROSet II. Click on the NIC with WOL
October 2007
a. Enable Intel WOL by typing 'ibautil –nic=X –wole' where X is the
number of the NIC in the display.
b. Enable Broadcom NX1 WOL by typing 'b57udiag –w 1 –c X' where X
is the number of the NIC in the display.
c.
Enable Broadcom NX2 WOL by typing 'uxdiag –c X –wol 1' where X
is the number of the NIC in the display.
Page 8
Dell Enterprise Product Group