Dell MD1400-16TB Manual de instalación - Página 33
Navegue en línea o descargue pdf Manual de instalación para Almacenamiento Dell MD1400-16TB. Dell MD1400-16TB 43 páginas. Netwitness platform xdr. powervault
PowerVault (Dell MD1400 - 16TB) Setup Guide
3. Connect the other end of the SAS cables to the External Storage units. See
a. Connect the Primary Port 1 of the first PowerVault to Port 0 of the PERC Card on the
left using a cable with square Mini-SAS (Codename SFF-8088) to square Mini-SAS
(Codename SFF-8088) connectors.
b. Daisy chain up to three additional PowerVaults to the first PowerVault using cables with
square Mini-SAS (Codename SFF-8088) to square Mini-SAS (Codename SFF-8088)
connectors.
c. Connect the Primary Port 1 of the first 15-Drive DAC to Port 0 of the PERC Card on
the right using a cable with rectangular Mini-SAS HD (Codename SFF-8614) to square
Mini-SAS (Codename SFF-8088 connectors.
d. Daisy chain up to three additional 15-Drive DACs to the first 15-Drive DAC using cables
with rectangular Mini-SAS HD (Codename SFF-8614) to rectangular Mini-SAS HD
(Codename SFF-8614) connectors.
The following figure shows an NetWitness Series 5 (R630) host connected to four
PowerVaults and four 15-Drive DACs.
33
Install PowerVaults and 15-Drive DACs on a Series 5 or Series 6 Host (Mixed
Mode)