Install the SFP and SFP+ Optics
The chassis are shipped as follows:
•
The S55 has 4 SFP optical ports in the PSU side of the chassis in addition to
the optional SFP+ optical modules.
•
The S60 has 4 SFP optical ports in the front of the chassis in addition to the
optional SFP+ optical modules.
CAUTION: Electrostatic discharge (ESD) damage can occur if components
are mishandled. Always wear an ESD-preventive wrist or heel ground strap
when handling the chassis and its components.
WARNING: Follow all warning labels when working with optical fibers.
Always wear eye protection when working with optical fibers. Never look
directly into the end of a terminated or unterminated fiber or connector as it
may cause eye damage.
Step
Task
Position the SFP or SFP+ so it is in the correct position. (The optic has a
1
key that prevents it from being inserted incorrectly.).
Insert the optic into the port until it gently snaps into place.
2
NOTE: For details on Dell Force10 supported optics, refer to
http://www.force10networks.com/products/specifications.asp
Power Up Sequence
Supply Power and Power Up the System
Dell Force10 recommends re-inspecting your system prior to powering up.
Verify that:
•
The equipment is properly secured to the rack and properly grounded.
•
The equipment rack is properly mounted and grounded.
•
The ambient temperature around the unit (which may be higher than the
room temperature) is within the limits specified for the unit.
•
There is sufficient airflow around the unit.
Installing the Hardware