También para Dell PowerEdge M1000e: Manual de actualización (44 páginas), Manual de actualización (21 páginas), Manual de actualización (14 páginas), Manual de instalación (7 páginas), Manual de introducción (12 páginas), Manual de introducción (12 páginas), Especificaciones (3 páginas), Manual de introducción (14 páginas), Manual de introducción (12 páginas), Primeros pasos (2 páginas), Manual de referencia (17 páginas)

Dell PowerEdge M1000e Manual de uso

Network-Attached Cluster

A network-attached cluster is a cluster configuration where all cluster nodes
are attached to a single storage system or to multiple storage systems through
a network using a redundant switch fabric. Network-attached cluster
configurations provide flexibility, expandability, and performance with either
iSCSI or Fibre Channel storage arrays.
Network-Attached Cluster Configured With an Internal Fabric
An internal fabric incorporates switch modules that do not connect to
external switches. Each server module I/O port is internally connected to a
port on a switch module. Up to two storage systems can be connected to the
outgoing ports on a switch module with internal fabric.
Cabling One PowerEdge Server Enclosure to One Storage System
In this configuration, a PowerEdge M1000e server enclosure is connected to
Dell|EMC CX3-20 storage system. The server and storage components in
your configuration may vary.
To cable one PowerEdge server enclosure to Dell|EMC CX3-20 storage
system:
1 Connect a cable from Fibre Channel switch module 1 to SP-A fibre port 0
(first fibre port).
2 Connect a cable from Fibre Channel switch module 1 to SP-B fibre port 1
(second fibre port).
3 Connect a cable from Fibre Channel switch module 2 to SP-A fibre port 1
(second fibre port).
4 Connect a cable from Fibre Channel switch module 2 to SP-B fibre port 0
(first fibre port).
Figure 2-3 shows how to cable a PowerEdge M1000e sever enclosure to the
CX3-20 storage system. The server module's dual-port Fibre Channel
daughter card and Fibre Channel switch modules are connected internally in
the system chassis.
32
Cabling Your Blade Cluster Hardware