Miele PW 6055 Plan de instalaciones - Página 10

Navegue en línea o descargue pdf Plan de instalaciones para Lavadora Miele PW 6055. Miele PW 6055 11 páginas.

OS 440
Cold water
Hot water
Alternative water
supply
(Optional)
Drainage via
dump valve
Installationsplan PW 6055/PW 6065 AV/LP EL
Stand: 02.05.2005
3. Standard voltage (as supplied)
Frequency
Rated load
Fuse rating
Connection cable, min. cross-section
Length of supply lead (supplied)
Plug and socket connection in accordance with IEC 60309
recommended to facilitate electrical safety tests.
Install mains isolator according to IEC 60947 on hard-wired
connection.
Wall socket or mains isolator must be accessible after
installation.
The use of an earth leakage circuit breaker (ELCB) is strongly
recommended. If an ELCB is fitted, it must be a Type B RCD
able to cope with rectified three-phase supplies.
If necessary, equipotential bonding with good galvanic contact
must be provided in accordance with all appropriate national
and local regulations.
Min. flow pressure
Max. pressure
Max. throughput (if hot water supply is not available)
On-site connection thread according to DIN 44 991
Length of connection hose (parts supplied: 1 connection
hose)
Water requirements (average for 60°C programme)
Standard connection [with hot water connection]
PW 6055
(PW 6065)
Additional requirements if hot water supply is not available.
Max. temperature
Min. flow pressure
Max. pressure
Max. throughput
On-site connection thread according to DIN 44 991
Length of connection hose (parts supplied: 1 connection
hose)
Water requirements (average for 60°C programme)
Standard connection [with hot water connection]
PW 6055
(PW 6065)
In absence of hot water, use blind stopper supplied and
reprogramme controls to cold water intake.
Min. flow pressure
Max. pressure
Max. throughput (if hot water supply is not available)
On-site connection thread according to DIN 44 991
Length of connection hose (parts supplied: 1 connection
hose)
Water requirements (average for 60°C programme)
Standard connection [with hot water connection]
PW 6055
(PW 6065)
When using an alternative water supply, the following
volumes can be deducted from hot or cold water supplies:
Deduction from cold water requirements
Deduction from hot water requirements
Max. temperature
Machine drain connection (d
On-site drain connection (d
int
Max. transient throughput
Vented drainage required. If ventilation is insufficient, fit Miele
kit, Mat. no. 05238090.
Drain manifolds serving several machines must be of
sufficient cross-section.
PW 6055
PW 6055
× s × l) [DN 70]
ext
× s × l) [DN 70 sleeve]
V
3 AC 440
Hz
60
kW
5.05
A
3 × 16
mm²
4 × 1.5
mm
2000
kPa
100
kPa
1000
l/min
10
(11)
Inch
¾" external thread
mm
1500
l/h
approx. 36
°C
70
kPa
100
kPa
1000
l/min
11
Inch
¾" external thread
mm
1500
l/h
approx. 13
kPa
100
kPa
1000
l/min
11
Inch
¾" external thread
mm
1500
l/h
approx. 14
l/h
approx. 4
l/h
approx. 10
°C
70
mm
75 × 1.9 × 40
mm
75 × 1.9 × 50
l/min
50
Seite 10