Safety regulations prohibit the fitting
of this cooker hood above a solid
fuel stove.
For safety reasons the
the cooker/hob and the bottom of
the cooker hood should be at least:
– 450 mm above electric hobs
and cookers.
– 650 mm above gas hobs and
cookers
– 650 mm above an open grill
from our range.
See "Warning and Safety
instructions" for further information.
A distance of 650 mm above electric
cookers/hobs may be preferable to give
more working space.
22
between the top of
(Air extraction mode only,
not for operation with an external motor)
^ If a non-return valve is not present in
the venting system, the non-return
flap supplied must be fitted onto the
exhaust stub in the motor unit. The
flaps must open upwards.
^ Turn the non-return flap slightly
anti-clockwise to secure it.
^ A C 100 mm or C 125 mm adapter
must be fitted to the exhaust stub to
suit the exhaust ducting being used.
Turn it slightly anti-clockwise to secure
it (not for use with an external motor).