Miller XMT 304 CC/CV Manual del usuario - Página 18

Navegue en línea o descargue pdf Manual del usuario para Sistema de soldadura Miller XMT 304 CC/CV. Miller XMT 304 CC/CV 40 páginas. Arc welding power source

Miller XMT 304 CC/CV Manual del usuario

4-1. Important Information Regarding CE Products (Sold Within The EU)

A. Information On Electromagnetic Fields (EMF)
!
This equipment shall not be used by the general public as the EMF limits for the general public might be exceeded during welding.
This equipment is built in accordance with EN 60974−1 and is intended to be used only in an occupational environment (where the general public
access is prohibited or regulated in such a way as to be similar to occupational use) by an expert or an instructed person.
Wire feeders and ancillary equipment (such as torches, liquid cooling systems and arc striking and stabilizing devices) as part of the welding
circuit may not be a major contributor to the EMF. See the Owner's Manuals for all components of the welding circuit for additional EMF exposure
information.
S
The EMF assessment on this equipment was conducted at 0.5 meter.
S
At a distance of 1 meter the EMF exposure values were less than 20% of the permissible values.
B. Information On Electromagnetic Compatibility (EMC)
!
This Class A equipment is not intended for use in residential locations where the electrical power is provided by the public low
voltage supply system. There can be potential difficulties in ensuring electromagnetic compatibility in those locations, due to con-
ducted as well as radiated disturbances.
!
This equipment does not comply with IEC 61000−3−12. If it is connected to a public low voltage system, it is the responsibility of
the installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the equip-
ment may be connected.

4-2. Serial Number And Rating Label Location

The serial number and rating information for this product is located on the rear panel. Use rating label to determine input power requirements and/or
rated output. For future reference, write serial number in space provided on back cover of this manual.

4-3. Specifications

Rated Welding
Voltage
Output
Range
300 A @
32 Volts DC,
10 − 35
60% Duty Cycle
*While idling
OM-233 045 Page 14
SECTION 4 − INSTALLATION
Maximum
Amperage
Open-Circuit
Range
Voltage DC
5 − 400
90
Amperes Input
at Rated Load
IP Rating
Output 50/60 Hz
400 V
17.0
23
(0.15*)
ce-emc 2 2011-09
KVA
KW
12.4
11.5
(0.09*)