General Installation

Water Pressure
Electrical Supply
Existing Plumbing
Unit Location
Bypass Valves
Plumbing
Iron free water
Birm filter
Air vent
Pressure tank
Air injector
Pressure switch to
pump
Figure 5. Standard Installation
Media Installation (When Necessary)
Remove the valve from the mineral tank.
Temporarily plug the open end of the central pipe in the tank to insure that no media or gravel falls down into the distribution.
Fill mineral tank one quarter full of water to protect distribution during gravel installation.
Slowly and carefully add the gravel support bed and the filtration media leveling each layer as it is placed into the tank.
Unplug the riser tube, carefully position the valve over it and turn the valve into the threads in the fiberglass tank, tightening
securely into tank.
Note:
Ensure that the internal O-ring in the valve fits securely over the riser tube. Silicone grease (#13691) or other food grade
lubricant may be applied to the O-ring to ease installation of the riser tube. DO NOT use petroleum based lubricants as
they will cause swelling of O-ring seals.
Minimum 25 PSI
Uninterrupted AC 115V
Free of any deposits or build-ups inside pipes.
Locate close to drain and connect according to plumbing codes
Always provide for bypass valve if unit is not equipped with one.
Softener and or other water treatment equipment should be
installed to local plumbing codes
CAUTION
Do not exceed 120 psi water pressure.
Do not exceed 110°F water temperature.
Do not subject unit to freezing
conditions.
Iron free water
Well water from
pump
Iron free water
Birm Filter
Air vent
Secondary Pressure tank
Air injector
Pressure switch to
solenoid
Figure 7. Split Stream Installation
Birm filter
Air vent
Pressure tank
Air injector
Pressure switch
Figure 6. Municipal Supply Installation
Secondary raw
water line
Primary Pressure tank
NC Solenoid valve
Pressure switch to well
pump
Well water from
pump
NC Solenoid valve
Municiple water
supply
10