Axor Citterio E 36431 9 Series Instrucciones de uso/montaje - Página 2
Navegue en línea o descargue pdf Instrucciones de uso/montaje para Productos de fontanería Axor Citterio E 36431 9 Series. Axor Citterio E 36431 9 Series 12 páginas.
0 2
EN
S A F E T Y N O T E S
Gloves should be worn during installation to prevent crushing and cutting injuries.
Children as well as adults with physical, mental and ⁄or sensoric impairments must
not use this shower system without proper supervision. Persons under the influence
of alcohol or drugs are prohibited from using this shower system.
Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
The product may not be used as a holding handle. A separate handle must be
installed.
The product may only be used for bathing, hygienic and body cleaning purposes.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and tested as per the applicable
standards.
⁄ The plumbing codes applicable in the respective countries must be observed.
⁄ The mesh washer must be insert to protect the shower against incoming dirt by
pipework. Incoming dirt leads to defects or⁄and can damage parts of the shower;
such caused faults voids all liability and guarantee claims.
T E C H N I C A L D A T A
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Thermal disinfection:
⁄ The product is exclusively designed for drinking water!
⁄ Safety against backflow
S Y M B O L D E S C R I P T I O N
Do not use silicone containing acetic acid!
F A U L T
⁄ Insufficient water
⁄ Crossflow, hot water being forced into cold water pipe, or
vice versa, when mixer is closed
⁄ Spout temperature does not correspond with temperature
set
⁄ Temperature regulation not possible
⁄ Safety stop button not operating
⁄ Valve stiff
⁄ Shower or spout dripping
A S S E M B L Y (see page 04)
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
70°C ⁄ 4 min
C A U S E
⁄ Supply pressure inadequate
⁄ Regulator filter dirty
⁄ Shower filter seal dirty
⁄ Backflow preventers dirty or leaking
⁄ Thermostat has not been adjusted
⁄ Hot water temperature too low
⁄ thermo cartridge calcified
⁄ For new installations: basic body incorrectly connected
(should be: cold right, hot left) or installed with 180° rotation
⁄ Spring defective
⁄ Button calcified
⁄ Shut-off unit damaged
⁄ Dirt or sedimentation on valve seat, shut-off unit damaged
A D J U S T M E N T (see page 04)
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the output
differs from the temperature set on the thermostat.
S A F E T Y F U N C T I O N (see page 05)
The desired maximum temperature for example max. 42°C can be pre-set
thanks to the safety function.
Hot and cold supplies are reversed (see page 06)
M A I N T E N A N C E (see page 06)
⁄ The check valves must be checked regularly according to EN 806-5 in
accordance with national or regional regulations (at least once a year).
⁄ To guarantee the smooth running of the thermostat, it is necessary from
time to time to turn the thermostat from total hot to total cold.
D I M E N S I O N S (see page 07)
F L O W D I A G R A M (see page 07)
Hand shower
Bath Spout
S P A R E P A R T S (see page 09)
XX = Colors
00 = Chrome Plated
14 = Brushed Bronze
30 = Polished Redgold
67 = Matt Black
S P E C I A L A C C E S S O R I E S (order as an extra)
extension 60 mm #92135000 (see page 09)
C L E A N I N G (see page 08)
O P E R A T I O N (see page 05)
R E M E D Y
⁄ Check water pressure (If a pump has been installed check to
see if the pump is working).
⁄ Clean filter in front of the mixer and on the MTC-thermo car-
tridge
⁄ Clean filter seal between shower and hose
⁄ Clean backflow preventers, exchange if necessary
⁄ Adjust thermostat
⁄ Increase hot water temperature to 42 °C to 60 °C
⁄ Exchange thermo cartridge
⁄ Install function block turned through 180° (see page 06)
⁄ Clean spring and ⁄or button, exchange if necessary
⁄ Exchange shut-off unit
⁄ Clean or exchange shut-off unit