PILOT-TONE INDICATOR
In many PA/VA systems, a high-frequency pilot-tone is
continuously fed to the loudspeakers for load monitoring
purposes. This permits load and cable integrity to be
constantly verified. An LED is fitted to the front panel of the
ADC range of speakers, which illuminates on detection of a
pilot-tone. The LED is visible with the grille installed, and is
a useful check that the system is operational.
®
The AXYS
PB-400 and PB-800 amplifiers include a suitable
pilot-tone generator; other manufacturers' equipment may
also be suitable. The pilot-tone should be in the frequency
range 19 to 25 kHz, and of at least 5 Vrms amplitude
(relative to the 100 W tap setting) for the LED to illuminate.
Pilot-tones of other frequencies and/or levels may be used
if the fault monitoring system demands them; the
illumination of the LED is not essential for such a system to
operate correctly.
14
SPEAKER PROTECTION
In a PA/VA system, it is important that the failure of a single
loudspeaker does not incapacitate the rest of the system.
The ADC range of speakers incorporate three protection
systems to prevent this.
1. The glass fuse used to select the internal transformer
tapping is designed to protect against excessive current
being drawn by the unit. The fuse is a standard 20 mm
diameter 1 A anti-surge type. Only replace this with a
fuse of the same type and rating. In the event of the
fuse needing replacement, remove the fuseholder from
the PCB (noting the tap setting). The fuse can be
removed from the holder by inserting a small
screwdriver or similar through the holes in the top of
the holder. Refer to fig. 9.1
2. ADC units also incorporate a separate thermal fuse in
series with the 100 V/70 V input. This is intended as fail-
safe device, which goes open-circuit if the internal
temperature becomes excessive, such as would occur
in the event of a fire. Thus a local fire which damages a
single speaker on a system does not cause other
speakers elsewhere to fail, as the damaged unit is
removed from the speaker circuit.
3. A ceramic connector ensures that the terminal will not
melt in a fire situation and short out the audio line.