Architectural Area Lighting SC5 Manual de instrucciones de instalación - Página 5

Navegue en línea o descargue pdf Manual de instrucciones de instalación para Luz exterior Architectural Area Lighting SC5. Architectural Area Lighting SC5 16 páginas.

INSTALLATION INSTRUCTIONS
FIXTURE INSTALLATION
1) TURN OFF POWER.
2) ADJUST FIXTURE HEAD TO THE DESIRE
POSITION AND SECURE WITH (2) BUTTON HEAD SCREWS.
3) MAKE WIRE CONNECTION FROM FIXTURE TO POLE.
(NOTE: ASSEMBLY MUST BE GROUNDED TO INCOMING
EQUIPMENT GROUND SUPPLY).
4) SLIP FITTER OVER TOP OF POLE AND SECURE FITTER WITH (6)
STAINLESS STEEL SET SCREWS.
LAMP INSTALLATION
5) TO INSTALL LAMP, INSERT FINGERS INTO SLOTS
AND PULL BOTH LATCHES BACK SIMULTANEOUSLY.
6) OPEN THE BOTTOM HALF HOUSING AND
INSTALL PROPER LAMP (BY OTHERS).
CLOSE BOTTOM HALF HOUSING.
SERVICING BALLAST
7) LOOSEN BOTH SCREWS AND ALLOW
BALLAST TRAY TO HANG DOWNWARD.
8) SERVICE BALLAST.
9) CLOSE BALLAST TRAY AND SCREW
BACK ON THE UPPER HOUSING.
16555 East Gale Avenue
City of Industry, CA 91745
(626)968-5666
(2) BUTTON
HEAD SCREWS
TWIN CURVED ARMS
LATCHES
SEE NOTES #5 & #6
FIXTURE HEAD
SEE NOTES #7 THRU #9
BALLAST TRAY
(6) STAINLESS STEEL SCREWS
WIRE CONNECTORS (BY OTHERS)
DATE
DATE
10/20/2005
CATALOG NUMBER
TSC4 / TSC5
APPRVD
PART NO.
A96268
REV.
A