ABB vital 1 Manual de instrucciones original - Página 9

Navegue en línea o descargue pdf Manual de instrucciones original para Controlador ABB vital 1. ABB vital 1 20 páginas. Safety controller
También para ABB vital 1: Manual (14 páginas)

ABB vital 1 Manual de instrucciones original
Warning! All power to the device must be disconnected before the connection blocks may be removed.
Connection of S1
S1 must be connected to B1 when an EVEN amount of sensors are connected to the Vital 1 dynamic safety circuit
(i.e. the number of sensors in series between T1 and R1). S1 must be disconnected when an ODD amount of
sensors are connected to the dynamic safety circuit.

Connection examples

Connection example: Vital 1 with Tina 8A and different types of safety devices
Caution! All cable colours according to ABB JOKAB Safety standard cables.
2TLC172156M0201, rev. C
9
www.abb.com/jokabsafety
2016-07-04