SEQUENCE OF OPERATION
With power supplied to indoor and outdoor units,
transformer is energized.
On a call for cooling, the thermostat makes circuits R−Y
and R−G. Circuit R−Y energizes contactor, starting
outdoor fan motor and compressor. Circuit R−G
energizes indoor unit blower relay, starting indoor blower
motor.
When thermostat is satisfied, its contacts open,
de−energizing contactor and blower relay. Compressor
and motors stop.
NOTE: If indoor unit is equipped with a time−delay relay
circuit, the blower runs an additional length of time to
increase system efficiency.
NOTE: The RED (R) low voltage lead wire is provided
only for powering the Comfort Alert device. To utilize the
Comfort Alert device, connect the RED (R) low voltage
lead wire directly to 24 VAC hot at the indoor unit or
thermostat. Use one of the spare wires in the thermostat
cable to bring 24 VAC hot out to the outdoor unit. If there
are no spare wires in the thermostat cable, leave the
insulation on the end of the RED low voltage lead wire to
avoid an electrical short. The air conditioner will
function normally without the RED (R) low voltage
lead wire connected.
421 01 5301 02
The Comfort Alert device operates by monitoring the
compressor power leads and the thermostat demand
signal (Y terminal). It draws constant 24 VAC power at
the R and C terminals.
MAINTENANCE
Condensate Drain
During the cooling season, check monthly for free flow of
drainage and clean if necessary.
Cleanliness
These tips will help keep the air conditioner looking better
and working more efficiently:
1. Free flow of air is essential. Keep fences, shrubs,
trash cans, and other obstructions at least 18
inches (0.5m) from all coil inlets.
2. Keep the coil free of grass clippings, leaves,
weeds, and other debris.
NOTE: Coil may occasionally require cleaning with a
liquid solution. The coil must be cold when
cleaning. Use an alkaline based cleaner only.
Cleaning a hot coil or using an acid based cleaner
will remove the paint from the fins and may clog
the coil.
3. Never use a weather cover over the outdoor unit
unless it is a ventilated type or made of breathable
fabric that will allow moisture to evaporate rapidly.
A cover that holds moisture in the unit will cause
more rust build−up and damage than normal
exposure to weather.
Specifications subject to change without notice.