Siemens Dishwashers Manual de instrucciones - Página 23

Navegue en línea o descargue pdf Manual de instrucciones para Lavavajillas Siemens Dishwashers. Siemens Dishwashers 28 páginas. Dishwasher
También para Siemens Dishwashers: Manual de instrucciones (30 páginas), Manual de instrucciones (30 páginas)

Siemens Dishwashers Manual de instrucciones
– After installing the appliance, ensure
that the plug is easily accessible.
(see Electrical connection)
– Some models:
The plastic housing on the water
connection contains an electric valve,
the connecting cables are in the supply
hose. Do not cut through this hose,
do not immerse the plastic
housing in water.
ã=
Warning
If the appliance is not in a cavity and a
side panel is accessible, the door hinge
area must be covered at the side
for reasons of safety (risk of injury).
The covers are available as optional
accessories from customer
service or specialist outlets.

Delivery

Your dishwasher has been checked
thoroughly in the factory to ensure that it is
in working order. This may cause small
water stains. These will disappear after the
first wash cycle.

Technical specifications

Weight:
max. 45 kg
Voltage:
220–240 V, 50 Hz or 60 Hz
Connected load:
2.0–2.4 kW
Fuse:
10/16 A (UK 13A)
Water pressure:
at least 0.05 MPa (0.5 bar), maximum
1 MPa (10 bar). At a higher water
pressure: connect pressure-reducing valve
ahead.
Inlet rate:
minimum 10 litres/minute
Water temperature:
cold water; hot water max. temperature
60 °C.

Installation

The required installation dimensions can
be found in the installation instructions.
Level the appliance with the aid of the
height-adjustable feet. Ensure that the
appliance is situated securely on the floor.
– A built-under or integrated appliance
which is installed subsequently as a
free-standing appliance must be
secured to prevent it from overturning,
e.g. by screwing it to the wall or by
installing it under a continuous worktop
which is screwed to adjacent
cupboards.
– The appliance can easily be
installed in a fitted kitchen between
wooden and plastic walls.

Waste-water connection

– The required work sequence can be
found in the installation instructions. If
required, fit a siphon with an drainage
connection.
– Connect the waste-water hose to the
drainage connection of the siphon with
the enclosed parts.
Ensure that the drainage hose is not
kinked, crushed or twisted and that
there is no cover plate in the drainage
to prevent the waste water from flowing
out!

Fresh water connection

– Connect the fresh-water connection to
the tap according to the installation
instructions with the enclosed parts.
Ensure that the fresh-water connection
is not kinked, crushed or twisted.
– When replacing the appliance, always
use a new water supply hose.
Water pressure:
at least 0.05 MPa (0.5 bar), maximum
1 MPa (10 bar). At a higher water
pressure: connect pressure-reducing valve
ahead.
Inlet rate:
minimum 10 litres/minute
Water temperature:
cold water preferred; hot water max.
temperature 60 °C.
en
23