ABB ACQ580-01 Series Manual de instalación rápida y puesta en marcha - Página 13
Navegue en línea o descargue pdf Manual de instalación rápida y puesta en marcha para Accionamientos de CC ABB ACQ580-01 Series. ABB ACQ580-01 Series 17 páginas. Ul type 4x (ip66) drives, nec types
También para ABB ACQ580-01 Series: Manual (16 páginas), Manual de instalación rápida y puesta en marcha (17 páginas), Manual de instalación rápida y puesta en marcha (16 páginas)
Warning Fault
Aux. code
AFF6
-
Identification run
-
FA81
Safe torque off 1
-
FA82
Safe torque off 2
Ratings, fuses and typical power cable sizes
ACS580-
Nominal ratings
01-...
Input current Output
current
I
I
I
1
1
2
(480 V)
A
A
U
= 3-phase 230 V
n
04A7-2
4.7
-
4.7
06A7-2
6.7
-
6.7
07A6-2
7.6
-
7.6
012A-2
12
-
12
018A-2
16.9
-
16.9 -
025A-2
24.5
-
24.5 -
032A-2
31.2
-
31.2 -
047A-2
46.7
-
46.7 -
060A-2
60
-
60
U
= 3-phase 400 V or 480 V
n
02A7-4
2.6
2.1
2.6 2.1
03A4-4
3.3
3
3.3 3
04A1-4
4
3.4
4
05A7-4
5.6
4.8
5.6 4.8
07A3-4
7.2
6
7.2
09A5-4
9.4
7.6
9.4 7.6
12A7-4
12.6
11
12.6 11
018A-4
17
14
17
026A-4
25
21
25
033A-4
32
27
32
039A-4
38
34
38
046A-4
45
40
45
1) P
= typical motor power with no overload capacity (nominal use). The kilowatt ratings apply to most IEC 4-pole motors. The horsepower
N
ratings apply to most NEMA 4-pole motors.
2) The recommended branch protection fuses that must be used to maintain the IEC/EN/UL 61800-5-1 listing.
3) For IEC installations, ABB recommends aR fuses. See hardware manual for guidelines in selecting between aR and gG fuses, and for additional
fuse alternatives.
4) IEC 61439-1: The drive is suitable for use on a circuit capable of delivering not more than 65 kA when protected by the fuses given in this table.
5) UL 61800-5-1, CSA C22.2 No. 274: The drive is suitable for use on a circuit capable of delivering not more than 100,000 symmetrical Amperes
(rms) at 600 V maximum when protected by the ABB recommended fuses, internally or externally.
6) IEC Installations: The cable sizing is based on max. 9 cables laid on a cable ladder side by side, three ladder type trays one on top of the other,
ambient temperature 30 °C, PVC insulation, surface temperature 70 °C (EN 60204-1 and IEC 60364-5-52/2001). For other conditions, size the
cables according to local safety regulations, appropriate input voltage and the load current of the drive.
7) NEC Installations: The cable sizing is based on NEC Table 310-15 for copper wires, 75 °C (167 °F) wire insulation at 40 °C (104 °F) ambient
temperature. Not more than three current-carrying conductors in raceway or cable or earth (directly buried). For other conditions, size the
cables according to local safety regulations, appropriate input voltage and the load current of the drive.
Terminal data for power connections
Input power cables with disconnect switch option (F253)
Frame
2T1, 4T2, 6T3
size
Min. wire size
(solid/stranded)
2
mm
AWG
R1
2.5
14
R2
2.5
14
R3
2.5
14
Description
The motor ID run occurs at the next start.
The Safe torque off circuit 1 is broken.
The Safe torque off circuit 2 is broken.
Fuses
Motor
gGfuse (IEC
1)
power
60269)
I
P
ABB type
2
n
(480 V)
kW
hp
-
0.75
1
OFAF000H25
-
1.1
1.5
OFAF000H25
-
1.5
2
OFAF000H25
-
3
3
OFAF000H25
4
5
OFAF000H25
5.5
7.5
OFAF000H40
7.5
10
OFAF000H40
11
15
OFAF000H63
-
15
20
OFAF000H63
0.75
1
OFAF000H4
1.1
1.5
OFAF000H6
3.4
1.5
2
OFAF000H6
2.2
3
OFAF000H10
6
3
3
OFAF000H10
4
5
OFAF000H16
5.5
7.5
OFAF000H16
14
7.5
10
OFAF000H25
21
11
15
OFAF000H32
27
15
20
OFAF000H40
34
18.5
25
OFAF000H50
40
22
30
OFAF000H63
Max. wire size
(solid/stranded)
2
mm
AWG
25
4
25
4
25
4
2)
3) 4)
uR/aR fuse
UL class
(DIN 43620)
T
Bussmann
type
170M1563
JJS-15
170M1563
JJS-15
170M1563
JJS-15
170M1563
JJS-15
170M1563
JJS-30
170M1565
JJS-40
170M1565
JJS-40
170M1566
JJS-80
170M1566
JJS-80
170M1561
JJS-15
170M1561
JJS-15
170M1561
JJS-15
170M1561
JJS-15
170M1561
JJS-15
170M1561
JJS-15
170M1561
JJS-15
170M1563
JJS-30
170M1563
JJS-30
170M1565
JJS-40
170M1565
JJS-60
170M1566
JJS-60
PE (same ground lug for all three frames)
Tightening torque Max. wire size
(solid/stranded)
2
N·m
lbf·ft
mm
6.2
4.6
2.5/2.5
6.2
4.6
10/10
6.2
4.6
35/35
Typical power cable
sizes, Cu
5)
2 6)
7)
mm
AWG
3×1.5 + 1.5 14
3×1.5 + 1.5 14
3×1.5 + 1.5 14
3×1.5 + 1.5 14
3×2.5 + 2.5 10
3×4.0 + 4.0 8
3×6.0 + 6.0 8
3×10 + 10
6
3×16 + 16
4
3×1.5 + 1.5
14
3×1.5 + 1.5
14
3×1.5 + 1.5
14
3×1.5 + 1.5
14
3×1.5 + 1.5
14
3×2.5 + 2.5 14
3×2.5 + 2.5 14
3×2.5 + 2.5 12
3×6 + 6
10
3×10 + 10
8
3×10 + 10
8
3×10 + 10
6
Tightening
torque
AWG
N·m
14
4.0
8
4.5
2
5.1
13
Frame
size
R1
R1
R1
R1
R1
R2
R2
R3
R3
R1
R1
R1
R1
R1
R1
R1
R2
R2
R3
R3
R3
lbf·ft
2.9
3.3
3.8