SENC 150
A variety of mounting conditions can be accomodated.
The machine configuration determines the brackets required
to mount the linear encoder.
Two typical mounting conditions are shown: flush and offset.
All fasteners shown on this page are supplied with the encoder
hardware.
Flush surfaces
1
2
1
M6 x 25 mm BHCS
(1/4"-20 x 1" BHCS)
M6 flat washer
Mounting surfaces are flush within 0.25 mm (0.010").
The reading head leveling screws are not required.
2
3
2
M4 x 25 mm SHCS low head
(8-32 x 5/8" SHCS low head)
(8-32 x 3/4" SHCS low head)
5 Mounting the encoder without backup spar
Offset surfaces
1
2
2
3
M4 hex nut
Mounting surfaces are offset.
Mounting without backup spar.
Use leveling screws in place of spacers or shims.
2
Space of ≤4.5 mm (≤0.18") use
reading head leveling screws!
2
3
11