Cisco TelePresence Server 7010 Primeros pasos - Página 15
Navegue en línea o descargue pdf Primeros pasos para Hardware de red Cisco TelePresence Server 7010. Cisco TelePresence Server 7010 16 páginas. 600w ac-input power supply and fan tray replacement
También para Cisco TelePresence Server 7010: Manual de instrucciones de sustitución (23 páginas), Manual de instrucciones de instalación (15 páginas), Manual de instalación (14 páginas), Manual de instrucciones de sustitución (18 páginas)
Technical specifications
Power requirements
Table 3: Cisco TS 7010 ratings
Rating
Nominal voltage
Current rating
Supply voltage range
Over-current protection
Ensure the supply to this unit is protected by a branch circuit protector rated by a
maximum of 20A.
Caution — over-current devices must meet applicable national and local
!
electrical safety codes and be approved for the intended application.
Operating environment
The unit must only be used within the following environmental conditions:
Table 4: Operating environment
Environment
Operating environment
Non-operating environment
Optimum operating environment
Anti-static precautions
When servicing or removing components or connections, first attach an anti-static
wrist strap to an appropriate earth point.
Value
115V to 230V 50/60 Hz
9A Maximum
100 to 240V 50/60 Hz
Temperature
0°C to 35°C
-10°C to 60°C
21°C to 23°C
Technical specifications
Humidity
10% to 95%
(non-condensing)
10% to 95%
(non-condensing)
45% to 50%
(non-condensing)
15