Appendix A – Macro Parameter Lists
18
Parameter
Item No.
Torque Control
Direction
10.02
Motor Fan Ack
10.06
HandAuto
10.07
Off2
10.08
OnOff1
10.15
StartStop
10.16
Jog1
10.17
Jog2
10.18
ConvFanAck
10.20
MainContAck
10.21
Ref1Mux
11.02
Ref1Sel
11.03
SpeedRef2301
Ref2Sel
11.06
AuxSpeedRef
Ref2Mux
11.12
MotPotUp
11.13
MotPotDown
11.14
MotPotMin
11.15
DO1 Index
14.01
DO1 Bit No
14.02
DO2 Index
14.03
DO2 Bit No
14.04
DO3 Index
14.05
DO3 Bit No
14.06
DO4 Index
14.07
DO4 Bit No
14.08
DO5 Index
14.09
DO5 Bit No
14.10
DO8 Select
14.16
Index AO1
15.01
Index AO2
15.06
TorqUsedMaxSe
20.18
TorqUsedMinSel
20.19
SpeedRef
23.01
FixedSpeed1
23.02
FixedSpeed2
23.03
TorqRefASel
24.29
TorqRefASel
25.10
TorqSel
26.01
TorqMuxMode
26.04
TorqMux
26.05
ExtFaultSel
30.31
ExtAlarmSel
30.32
USI Sel
16.09
All others
DCS800 Firmware manual supplement for North America (rev. 2.60, 2.70) Rev. b
Torque Limit*
NotUsed
NotUsed
NotUsed
NotUsed
NotUsed
NotUsed
DI-1
NotUsed
DI-7
DI-7
DI-8
DI-8
NotUsed
DI-1
NotUsed
DI-2
NotUsed
NotUsed
NotUsed
NotUsed
Close
Close
AI-1
SpeedRef2301
Open
Open
NotUsed
NotUsed
NotUsed
NotUsed
NotUsed
NotUsed
801
801
1
1
801
801
2
2
802
802
13
13
802
802
11
11
603
801
15
10
7
7
104
104
108
113
TorqMax
AI-2
TorqMin
Negate2018
100
0
0
75
0
100
Par1Sel
Par1Sel
AI-1
TorqRefA2501
Torque
Speed
Speed/Torq
TorqSel2601
DI-2
NotUsed
DI-3
DI-3
NotUsed
DI-4
Extended
Extended
not changed
not changed
2-Wire DC Contact US*
3-Wire DC Contact US*
NotUsed
NotUsed
NotUsed
NotUsed
NotUsed
NotUsed
NotUsed
NotUsed
DI-7
DI7DI8
DI-8
DI7DI8
DI-1
NotUsed
DI-2
NotUsed
NotUsed
NotUsed
DI-4
DI-4
Close
DI1
AI-1
Fixed speed1
SpeedRef2301
AI-1
Open
invert 1102
NotUsed
NotUsed
NotUsed
NotUsed
NotUsed
NotUsed
801
801
1
1
801
801
2
2
802
802
13
13
802
802
11
11
801
801
10
10
10
10
104
104
113
113
TorqMax
TorqMax
TorqMin
TorqMin
0
0
75
75
100
100
Par1Sel
Par1Sel
TorqRefA2501
TorqRefA2501
Speed
Speed
TorqSel2601
TorqSel2601
NotUsed
NotUsed
DI-3
DI-3
NotUsed
NotUsed
Extended
Extended
not changed
not changed
3-Wire Standard*
NotUsed
NotUsed
NotUsed
NotUsed
DI7DI8
DI7DI8
NotUsed
NotUsed
NotUsed
NotUsed
DI1
Fixed speed1
AI-1
invert 1102
NotUsed
NotUsed
NotUsed
801
1
801
2
802
13
802
11
801
10
7
104
113
TorqMax
TorqMin
0
75
100
Par1Sel
TorqRefA2501
Speed
TorqSel2601
NotUsed
DI-3
DI-4
Extended
not changed