ABB jokab safety Smile Tina Series Manual de instrucciones original - Página 8

Navegue en línea o descargue pdf Manual de instrucciones original para Unidad de control ABB jokab safety Smile Tina Series. ABB jokab safety Smile Tina Series 12 páginas. Emergency stop with indication

ABB jokab safety Smile Tina Series Manual de instrucciones original

5 Operation

LED indication

LED
LED on Tina

Information output signal attributes

The information output of the unit (pin-5) is set either high (+24 VDC) or low (0 VDC) depending on
four different input signals (pin-2):
Dynamic signal - Dynamic signal input exist, i.e. the safety circuit is OK up until this unit
No dynamic signal - Dynamic signal input does not exist, i.e. the safety circuit is interrupted
before this unit.
+24 VDC - A constant +24 VDC signal is applied = high (H)
0 VDC - The pin is connected to 0 VDC = low (L)
The information output signal depends on the input signal according to the table below. Note that if the
safety is interrupted; i.e. if the emergency button is pressed, the information output signal is always
low (L).
Input signal (pin-2)
Info output signal (pin-5)
The delay for switching the information signal output from high to low (H
is given in the table below.
Info output signal switch
Delay
NB: If the unit detects an error (short circuit or interruption) lasting shorter than 13 ms the information
output signal is set to low for 1.2 s (1200 ms) and then set to high again. This does not affect Vital
since it needs 22 ms to release. Pluto however does release, which means that a filter (20 ms) must
be implemented if this function is needed.
Warning! The information output signal is not a failsafe signal and should never be used for the
safety purpose(s).
8
Smile_Tina_Manual_(English)_v1A
2010-10-19
Indication
Description
Safety circuit closed
Green
(protection OK)
Safety circuit open
Green-Red (flash)
(protection OK)
Safety circuit interrupted
Red
(protection open)
Dynamic signal
High
H
L
~ 12 ms
Input signal on pin-2
Dynamic signal in
No dynamic signal in or 0 VDC in
+24 VDC in or safety circuit
interrupted
No dynamic signal
High
L
H
~ 0 ms
+24 VDC
0 VDC
Low
High
L) and low to high (L
H)
www.jokabsafety.com