Installation Procedure – Mobile Home
CAUTION: THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL
AND CEILING/ROOF MUST BE MAINTAINED.
Note: See "Combustion Air" section on page 11
1.
Position stove and fl oor protection with hole for combustion air in accordance with the
clearances as stated on the label and in Figure #3.
2. Mark the position for the hole in the ceiling and roof by using a string and plumb-bob.
3. Check that the intended location will not interfere with fl oor joists, ceiling joists or rafters
before proceeding further.
4. Cut a hole in the ceiling and roof to suit the chimney system and frame in the sides. The
chimney support is mounted to the framing.
5. Assemble chimney sections so the fi nished length is resting on the support and protruding
through the roof. Avoid having joints between ceiling and roof. Install radiation shield.
Assemble fl ashing and storm collar and be sure to maintain the vapour barrier at this
point. (Seal securely.) Attach rain cap and check fl ashing for leaks.
5. Install connector as per manufacturer's instructions.
6. To attach stove to fl oor, fi rst remove the leveling bolts from the legs. Then attach stove
to fl ooring using two 1/4" x 2" or longer lag screws through the leveling bolt holes.

Listed Chimney and Chimney Connector for Mobile Home Installation

This appliance, when installed in a Mobile Home, must be installed with:
A. One of the following 6" double-wall connector systems:
1. Security Model DL or DC
2. Oliver MacLeod Model PV
3. Energy Vent
4. Selkirk Metalbestos Model DS
B. As well as one of the following compatible chimney systems - All parts 6":
CANADA ONLY:
Security
S2100
Ceiling support
XSF
Rafter radiation shield
3' Chimney length
XL3
2' Chimney length
XL2
Roof fl ashing
XFA
Storm collar
XSC
Spark arrestor rain cap
XCPE
USA ONLY:
Security
S2100
Ceiling support
XSF
Rafter radiation shield
3' Chimney length
XL3
2' Chimney length
XL2
Roof fl ashing
XFA
Storm collar
XSC
Spark arrestor rain cap
XCPE
5. Metal Fab Model DW
6. Ameri-Tec Model DBSP
7. Industrial Chimney Model Excel Ultra-Black
8. Simpson Dura-Vent Model DVL
Pro-Jet
ICC
Selkirk
H.T.3000
Excel 2100 Sentinal CF Commander 5000
FCS
SF
CF-CSP
RRS
SL3
L3
CF-36SL
SL2
L2
CF-24
RF17
FA
CF-FRA
SC
SC
CF-SC
RCSA
CPE
CF-SA,CT
Pro-Jet
Security
Pro-Jet
H.T.3000
ASHT
HT3103
FCS
SF
FCS
RRS
RRS
SL3
L3
SL3
SL2
L2
SL2
RF17
FA
RF
SC
SC
SC
RCSA
CPE
RCSA
Energy Vent
CH6LCS
CH636
CH624
CH6TCF
CH6SC
CH6RC, SS
Metalbestos MetalFab
Ameritech
SSII
2100
TEC HS
T-SFA
TGCSP
6PL-CS
T-JSMH
TGRS
T-36
TG3
HS 36
T-24
TG2
HS 24
T-SFA
TGF
8RFFU
T-SC
TGSC
PL-ASCG
T-CT
TGC
6PL-MPC
10
Follow chimney and chimney
components manufacturer's
instruction for assembly and
installation.
ICC
Simpson Dura-Vent
Excel 103HT Dura/Plus Dura Tech
RDS/SQS
SDP-SB
SDP-SB
CL48
SDP-P
SDT-P
CL24
SDP-P
SDT-P
VF
SDP-F
SDT-F
SC
SDP-SC
SDT-SC
RCS
SDP-C
SDT-C
230611-20 ALT4