FOR 52W V-LINE FLOOD LIGHT WITH DIMMER
Universal voltage driver permits operation at 120V-277V,
50/60Hz
WAGO
DIM+(PURPLE)
DIMMER
WAGO
DIM-(GRAY)
WAGO
RED
RED(+)
(DC+)
VAUX/12V
WAGO
(YELLOW)
LED
BOARD
POWER
WAGO
ACL(BLACK)
L
WAGO
BLACK
BLACK(-)
(DC-)
WAGO
ACN(WHITE)
N
WAGO
GROUND
GROUND
INSTALLATION
EXPLODED DRAWING
Power Supply
Body
Reflector
Glass
Frame
2
Add: 1501 Industrial Way North, Toms River, NJ 08755 Phone: 866-ABB-8866 E-mail: [email protected]
Web: www.abblighting.com ©2015 ABBlighting, Inc. All rights reserved
LED V-LINE FLOOD LIGHT
Instructions Manual
FOR 80W & 100W V-LINE FLOOD LIGHT WITH DIMMER
Universal voltage driver permits operation at 120V-277V,
50/60Hz
WAGO
DIM+(BLUE)
DIMMER
WAGO
WAGO
RED
DIM-(WHITE)
RED(+)
(DC+)
LED
POWER
WAGO
L
BOARD
ACL(BROWN)
BLACK
WAGO
WAGO
BLACK(-)
(DC-)
N
ACN(BLUE)
WAGO
GREEN/YELLOW
GROUND
Power Supply Cover
Photo Control
Trunnion
INSTALLATION
OPTION 1: TRUNNION MOUNTING INSTALLATION
1. Using two srews to install trunnion to appropriate position.
2. Rotate fixture to appropriate position, and srew tightly. Fixture can adjust 180˚.
2. Rotate fixture to appropriate position, and srew
tightly. Fixture can adjust 180
OPTION 2: SLIP FITTER & KNUCKLE INSTALLATION
For 26W, 38W, 52W Knuckle
1. Screw Knuckle to the pole.
Add: 1501 Industrial Way North, Toms River, NJ 08755 Phone: 866-ABB-8866 E-mail: [email protected]
Web: www.abblighting.com ©2015 ABBlighting, Inc. All rights reserved
LED V-LINE FLOOD LIGHT
Instructions Manual
Trunnion
1. Using two srews to install trunnion to
appropriate position
˚
1. Screw knuckle to
the pole
3