Array Solutions Four Square Manual del usuario - Página 2

Navegue en línea o descargue pdf Manual del usuario para Sistemas de control Array Solutions Four Square. Array Solutions Four Square 10 páginas. Array controller
También para Array Solutions Four Square: Manual del usuario (12 páginas)

2
mm
) or larger gauge stranded wires will be adequate. The relays draw only 120 mA at 12 V DC.
Try to use a supply that has a 13.8 V+ DC output or more for very long runs.
Wire the control switch connector to the relay box per the following Table 1.
Control Switch Connector
1
2
3
4
G
Suggestion: use a connector on a short piece of cable so you may disconnect the control
unit from the control cable when not in use, or when a thunderstorm arrives. We also
recommend the use of a surge protector at the station end for the control cable and RF
cables, such as our AS-8-SP control line protector and our AS-303U coaxial cable surge
protector. A little money spent now can save valuable radios and other gear later. We also
have MOV protection inside the relay box.
Plug both the control line and power supply connectors into the back of the control box box.
Hot Switch Protection – to activate the hot switching safety feature, just plug an RCA PTT line
from your transceiver into the RCA jack in the back of the controller. When PTT is asserted
(GND) no relays will switch if a control pushbutton is accidentally pushed.
NETWORK – is for the ShackLan network and will allow control over the network for instance for
a remote station or for networking with other Hamation controllers.
See
http://hamation.com/

Relay Box

www.arraysolutions.com
2611 N. Beltline Rd.,Ste 109
Sunnyvale, TX, 75182, USA
Table 1
for more information.
Phone: +1 214 954 7140
Relay Box Terminal strip
1
2
3
4
Gnd - Ground
Four Square Manual, ver. 2.1
August 21 2017
2